Evidence map›Paper›PMID 37376731›Full record

ArticleThe American journal of case reports2023

Condyle Fracture Fixed with Custom-Made Titanium Mesh and a Miniplate: A Case Report.

Tadashi Kawai, Shinsuke Kawamata, Shuu Suzuki, Yuudai Ishikawa, Yuunosuke Ikeda, Erika Yasuge, Shintaro Kogi, Atsushi Ogawa, Mitsuru Izumisawa, Hiroyuki Yamada

Abstract readCase Reports
In one paragraph

Article in The American journal of case reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Tadashi KawaiDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Shinsuke KawamataDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Shuu SuzukiDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Yuudai IshikawaDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Yuunosuke IkedaDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Erika YasugeDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Shintaro KogiDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Atsushi OgawaDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Mitsuru IzumisawaDivision of Dental Radiology, Department of General Dentistry, Iwate Medical University, Morioka, Iwate, Japan.
Hiroyuki YamadaDivision of Oral and Maxillofacial Surgery, Department of Reconstructive Oral and Maxillofacial Surgery, School of Dentistry, Iwate Medical University, Morioka, Iwate, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Open reduction and internal fixation of condyle fractures are sometimes difficult for the upper region. This report presents a case of condyle fracture at the upper neck region treated with a custom-made titanium mesh and a titanium miniplate, which makes it easy to reposition the fragment and keep it in place. CASE REPORT A 20-year-old man was injured during a soccer match and was referred to our hospital with the symptom of trismus and deviation of the mandible to the left with an opened mouth. Fracture of the right condyle neck region was diagnosed; open reduction and internal fixation was planned under general anesthesia. A custom-made titanium mesh was prepared to make it easy to reposition the fragment and keep it in place because the reduction and fixation were expected to be difficult. The fracture region was exposed using the modified Risdon-Strasbourg approach. The segments were gripped with custom-made titanium mesh, and the condyle head was reduced easily. The segments were fixed with titanium mesh, a miniplate, and screws. Nine months after the operation, the mouth opening was good at 40 mm, there was no deviation of the mandible, and there was no breakage on the titanium mesh or plate. CONCLUSIONS This report presents a case of condyle fracture at the upper neck region reduced and fixed with a custom-made titanium mesh and a titanium miniplate, which make it easy to reposition the fragment and keep it in place.

Indexed as

Mandibular FracturesTitaniumAdultBone PlatesFracture Fixation, InternalHumansMaleSurgical MeshYoung AdultTitanium

Identifiers

PMID37376731
PMCPMC10316717

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.