Evidence map›Paper›PMID 37375188›Full record

ArticleMolecules (Basel, Switzerland)2023

Quantitative Evaluation of Interleukin-4 by Immunowall Devices Made of Gelatin Methacryloyl Hydrogel.

Yuto Banno, Takuma Nomiyama, Shoma Okuno, Sachiko Ide, Noritada Kaji

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Yuto BannoDepartment of Applied Chemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
Takuma NomiyamaDepartment of Applied Chemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
Shoma OkunoDepartment of Applied Chemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
Sachiko IdeDepartment of Applied Chemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.
Noritada KajiDepartment of Applied Chemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.ORCID 0000-0002-9828-873X
Kyushu University · JP

Funding

Japan Science and Technology Agency JPMJPF2107Japan Society for the Promotion of Science 21H01966Japan Society for the Promotion of Science JP19KK0140
6 · The paper itself

Abstract

Immunoassays, which use antigen-antibody reactions, are the primary techniques used to selectively quantify specific disease markers in blood. Conventional immunoassays, such as the microplate-based enzyme-linked immunosorbent assay (ELISA) and paper-based immunochromatography, are widely used, but they have advantages and disadvantages in terms of sensitivity and operating time. Therefore, in recent years, microfluidic-chip-based immunoassay devices with high sensitivity, rapidity and simplicity, which are compatible with whole blood assays and multiplex assays, have been actively investigated. In this study, we developed a microfluidic device using gelatin methacryloyl (GelMA) hydrogel to form a wall-like structure in a microfluidic channel and perform immunoassays inside the wall-like structure, which can be used for rapid and highly sensitive multiplex assays with extremely small sample amounts of ~1 μL. The characteristics of GelMA hydrogel, such as swelling rate, optical absorption and fluorescence spectra, and morphology, were carefully studied to adapt the iImmunowall device and immunoassay. Using this device, a quantitative analysis of interleukin-4 (IL-4), a biomarker of chronic inflammatory diseases, was performed and a limit of detection (LOD) of 0.98 ng/mL was achieved with only 1 μL sample and 25 min incubation time. The superior optical transparency over a wide range of wavelengths and lack of autofluorescence will help to expand the application field of the iImmunowall device, such as to a simultaneous multiple assay in a single microfluidic channel, and provide a fast and cost-effective immunoassay method.

Indexed as

Interleukin-4Microfluidic Analytical TechniquesEnzyme-Linked Immunosorbent AssayGelatinHydrogelsImmunoassayLab-On-A-Chip DevicesMethacrylatesGelatingelatin methacryloylHydrogelsInterleukin-4Methacrylatesgelatin methacryloyl hydrogelimmunoassayinterleukinlab on a chip

Identifiers

PMID37375188
PMCPMC10304311
OpenAlexW4380050951

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.