Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
In this work, a novel piezoelectric actuator based on the stick-slip principle is proposed. The actuator is constrained by an asymmetric constraint approach; the driving foot produces lateral and longitudinal coupling displacements when the piezo stack is extended. The lateral displacement is used to drive the slider and the longitudinal displacement is used to compress the slider. The stator part of the proposed actuator is illustrated and designed by simulation. The operating principle of the proposed actuator is described in detail. The feasibility of the proposed actuator is verified by theoretical analysis and finite element simulation. A prototype is fabricated and some experiments are carried out to study the proposed actuator's performance. The experimental results show that the maximum output speed of the actuator is 3680 μm/s when the locking force is 1 N under the voltage of 100 V and frequency of 780 Hz. The maximum output force is 3.1 N when the locking force is 3 N. The displacement resolution of the prototype is measured as 60 nm under the voltage of 15.8 V, frequency of 780 Hz and locking force of 1 N.