Evidence map›Paper›PMID 37374674›Full record

ArticleMaterials (Basel, Switzerland)2023

Micro-CT Evaluation of Microgaps at Implant-Abutment Connection.

Jakub Kowalski, Adam K Puszkarz, Mateusz Radwanski, Jerzy Sokolowski, Michal Cichomski, Rim Bourgi, Louis Hardan, Salvatore Sauro, Monika Lukomska-Szymanska

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Trial
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jakub KowalskiDepartment of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland.
Adam K PuszkarzFaculty of Material Technologies and Textile Design, Institute of Material Science of Textiles and Polymer Composites, Lodz University of Technology, 116 Zeromskiego Street, 90-924 Lodz, Poland.ORCID 0000-0002-1765-9093
Mateusz RadwanskiDepartment of Endodontics, Medical University of Lodz, 92-213 Lodz, Poland.ORCID 0000-0003-2333-0996
Jerzy SokolowskiDepartment of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland.
Michal CichomskiDepartment of Material Technology and Chemistry, Faculty of Chemistry, University of Lodz, Pomorska 163, 90-236 Lodz, Poland.ORCID 0000-0002-7638-7286
Rim BourgiDepartment of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon.ORCID 0000-0002-8003-2664
Louis HardanDepartment of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon.ORCID 0000-0001-8577-2285
Salvatore SauroDental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Cienciasde la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo ss/n, Alfara del Patriarca, 46115 Valencia, Spain.ORCID 0000-0002-2527-8776
Monika Lukomska-SzymanskaDepartment of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland.ORCID 0000-0002-6110-4298

Funding

RPLD.01.01.00-10-0002/17-00 Regional Operational Programme for Łódzkie 2014-2020
6 · The paper itself

Abstract

The assessment of microgaps at the implant-abutment interface is an important factor that may influence clinical success. Thus, the aim of this study was to evaluate the size of microgaps between prefabricated and customised abutments (Astra Tech, Dentsply, York, PA, USA; Apollo Implants Components, Pabianice, Poland) mounted on a standard implant. The measurement of the microgap was performed using micro-computed tomography (MCT). Due to 15-degree rotation of samples, 24 microsections were obtained. Scans were performed at four levels established at the interface between the abutment and the implant neck. Moreover, the volume of the microgap was evaluated. The size of the microgap at all measured levels varied from 0.1 to 3.7 µm for Astra and from 0.1 to 4.9 µm for Apollo (

Indexed as

abutmentdental implantmicro-computed tomographymicrogap

Identifiers

PMID37374674
PMCPMC10305145

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.