ReviewJournal of personalized medicine2023
Diagnosis of Left-Sided Mechanical Prosthetic Valve Thrombosis: A Pictorial Review.
Review in Journal of personalized medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 8 citations in OpenAlex.
- 4D TEE-Guided Thrombolysis for Mechanical Mitral Valve Obstruction.JACC. Case reports · 2026Article
- Massive Acute Thrombosis of a Mechanical Mitral Valve in a Young Patient on Acenocoumarin: A Case Report Comparing Surgical and Thrombolytic Approaches.Clinical case reports · 2025Article
- Short- and mid-term outcomes after redo surgical valve replacement.European journal of medical research · 2025Article
- Mechanical Mitral Valve Prosthesis Thrombosis: A Case Report.Acta medica Lituanic · 2025Article
- Prosthetic valve infective endocarditis with severe mitral stenosis caused byEuropean heart journal. Case reports · 2024Article
- Chordae Tendinea Rupture and Pulmonary Valve Vegetation in Pediatric Endocarditis: A Rare Condition.Cureus · 2024Article
- Intraoperative transesophageal echocardiography in liver transplantation: A systematic review of clinical utility in managing hemodynamic challenges and complications.Tzu chi medical journalReview
- Outcomes of Thrombolysis for Left-Sided Mechanical Valve Thrombosis: A 10-Year Retrospective Study.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/HemostasisArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although transcatheter valve therapy is rapidly evolving, surgical valve replacement is still required in many patients with severe left-side valve stenosis or regurgitation, the mechanical bi-leaflet heart valve being the standard prosthesis type in younger patients. Moreover, the prevalence of valvular heart disease is steadily increasing, especially in industrialized countries, and the problem of lifelong efficient anticoagulation of these patients remains fundamental, especially in the context where vitamin K antagonists continue to be the current standard of anticoagulation despite a level of oscillating anticoagulation. In this setting, avoiding prosthetic valve thrombosis after surgery is the number one objective for both the patient and the responsible physicians. Although rare, this complication is life threatening, with the sudden onset of acute cardiac failure such as acute pulmonary edema, cardiogenic shock, or sudden cardiac death and inadequate anticoagulation remaining the leading cause of prosthesis thrombosis, along with other risk factors. The availability of multimodal imaging techniques enables and encompasses to a full extent the diagnosis of mechanical valve thrombosis. The gold-standard diagnostic methods are transthoracic and transesophageal echocardiography. Moreover, 3D ultrasound has undoubted value in giving a more accurate description of the thrombus's extension. When transthoracic and transesophageal echocardiography are uncertain, the multidetector computer tomography examination is an important complementary imaging method. Fluoroscopy is also an excellent tool for evaluating the mobility of prosthetic discs. Each method complements the other to differentiate an acute mechanical valve thrombosis from other prosthetic valve pathologies such as pannus formation or infective endocarditis and aids the physician in accurately establishing the treatment method (surgical or pharmaceutical) and its optimal timing. The aim of this pictorial review was to discuss from an imagistic perspective the mechanical prosthetic aortic and mitral valve thrombosis and to provide an overview of the essential role of non-invasive exploration in the treatment of this severe complication.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.