Comparison of the New-Generation Self-Expanding NAVITOR Transcatheter Heart Valve with Its Predecessor, the PORTICO, in Severe Native Aortic Valve Stenosis.

Clemens Enno Eckel, Won-Keun Kim, Christina Grothusen, Vedat Tiyerili, Albrecht Elsässer, Dagmar Sötemann, Judith Schlüter, Yeong-Hoon Choi, Efstratios I Charitos, Matthias Renker and 4 more

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Review
  3. Pacemaker Implantation Rates With the Self-Expandable Navitor Valve.Journal of the American Heart Association · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Comparison of Latest Generation Intra- and Supra-Annular Self-Expanding Transcatheter Heart Valves for Aortic Valve-in-Valve Procedures.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025
    Article
  9. Intra- versus supra-annular self-expanding transcatheter heart valves in small aortic annuli.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025
    Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Clemens Enno EckelDepartment of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany.
Won-Keun KimDepartment of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany.
Christina GrothusenDepartment of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany.
Vedat TiyeriliDepartment of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany.
Albrecht ElsässerDepartment of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany.
Dagmar SötemannDepartment of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany.
Judith SchlüterDepartment of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany.
Yeong-Hoon ChoiDepartment of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany.ORCID 0000-0002-5796-9926
Efstratios I CharitosDepartment of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany.ORCID 0000-0003-0284-8200
Matthias RenkerDepartment of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany.ORCID 0000-0002-4756-5397
Christian W HammGerman Center for Cardiovascular Research (DZHK), Partner Site Rhine-Main, 55131 Bad Nauheim, Germany.
Guido DohmenDepartment of Cardiac Surgery, St. Johannes Hospital, 44137 Dortmund, Germany.ORCID 0000-0001-6577-7898
Helge MöllmannDepartment of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany.
Johannes BlumensteinDepartment of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThird-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce.

aimsThe aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems.

methodsData from 782 patients with severe native aortic stenosis treated with PORTICO (

resultsRates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%,

conclusionsThe NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.