Evidence map›Paper›PMID 37371393›Full record

ArticleBrain sciences2023

Real-Time MRI Monitoring of Liquid Embolic Agent (Onyx) Injection in a Swine Arteriovenous Malformation Model.

Michał Zawadzki, Miłosz Pinkiewicz, Mateusz Pinkiewicz, Jerzy Walecki, Piotr Walczak, Dominika Gołubczyk, Maria Sady, Zdzisław Gajewski

Open access · goldAbstract read
In one paragraph

Article in Brain sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Michał ZawadzkiDepartment of Radiology, Centre of Postgraduate Medical Education, 01-813 Warsaw, Poland.ORCID 0000-0002-3044-6690
Miłosz PinkiewiczFaculty of Medicine, Wroclaw Medical University, 50-368 Wrocław, Poland.ORCID 0000-0002-1680-7410
Mateusz PinkiewiczDepartment of Diagnostic Imaging, Mazowiecki Regional Hospital in Siedlce, 08-110 Siedlce, Poland.ORCID 0000-0003-2803-0503
Jerzy WaleckiDepartment of Radiology, Centre of Postgraduate Medical Education, 01-813 Warsaw, Poland.
Piotr WalczakProgram in Image Guided Neurointerventions, Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland, Baltimore, MD 21201, USA.ORCID 0000-0002-3733-3322
Dominika GołubczykCenter for Translational Medicine, Warsaw University of Life Sciences, 02-787 Warsaw, Poland.
Maria SadyCenter for Translational Medicine, Warsaw University of Life Sciences, 02-787 Warsaw, Poland.
Zdzisław GajewskiCenter for Translational Medicine, Warsaw University of Life Sciences, 02-787 Warsaw, Poland.
Warsaw University of Life Sciences · PLMinistry of Interior and Administration · PLWroclaw Medical University · PLUniversity of Maryland, Baltimore · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The paradigm is gradually shifting, with radiosurgery and endovascular embolization being increasingly chosen over surgical resection in the selected cases of brain arteriovenous malformations. Routinely used X-ray monitoring of liquid embolic infusion has very good spatial and temporal resolution but is not without significant drawbacks regarding poor visualization of the complex AVM angioarchitecture, especially after many embolizations in the past and therefore limiting the technical ability of the embocure-total occlusion of the feeding arteries, nidus, and draining veins. The purpose of this study was to evaluate the use of real-time MRI guidance in endovascular embolization with Onyx (instead of X-ray) in a single swine rete mirabile (RM) AVM model in order to provide the scaffolding for the real-time MRI guidance method. Onyx propagation was observed in real-time dynamic GE-EPI scan with initial ipsilateral RM filling followed by main cerebral arterial branch distribution. The relatively bright signal within RM and the brain prior to Onyx injection provided a good background for the dark, low signal of the embolic agent spreading in rete mirabile and brain arteries. X-ray picture confirmed Onyx cast distribution at the end of the procedure. In this initial experience, real-time MRI seems to be a promising method that may significantly improve liquid embolic agent infusion monitoring in the future, although requiring further development before clinical use.

Indexed as

AVMembolisationreal time MRI monitoring

Identifiers

PMID37371393
PMCPMC10295955
OpenAlexW4379517736

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.