Evidence map›Paper›PMID 37369178›Full record

ArticleCytogenetic and genome research2023

Paper-Based Vertical Flow Immunoassay for the Point-of-Care Multiplex Detection of Radiation Dosimetry Genes.

Jerome Lacombe, Alexander J Summers, Ashkan Khanishayan, Yasaman Khorsandian, Isabella Hacey, Wyatt Blackson, Frederic Zenhausern

Abstract read
In one paragraph

Article in Cytogenetic and genome research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jerome LacombeCenter for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, Arizona, USA.
Alexander J SummersCenter for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, Arizona, USA.
Ashkan KhanishayanCenter for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, Arizona, USA.
Yasaman KhorsandianCenter for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, Arizona, USA.
Isabella HaceyCenter for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, Arizona, USA.
Wyatt BlacksonCenter for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, Arizona, USA.
Frederic ZenhausernCenter for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, Phoenix, Arizona, USA.

Funding

Sample Engineering CoreU19AI067773 · NIAID · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI AMUNDSON, SALLY A. · 2005 to 2024
$105.4M
Development of FAST-DOSE assay system for the rapid assessment of acute radiation exposure, individual radiosensitivity and injury in victims for a large-scale radiological incidentU01AI148309 · NIAID · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI TURNER, HELEN C · 2020 to 2024
$3.2M
Targeted Biomarker Panels and Pre-processing Device for the Rapid Assessment of Radiation Injury in Easily Accessible BiofluidsU01AI148307 · NIAID · GEORGETOWN UNIVERSITY · PI LAIAKIS, EVAGELIA CHRISTOS, ZENHAUSERN, FREDERIC · 2021 to 2025
$2.9M
NIAID NIH HHS U01 AI148307NIAID NIH HHS U01 AI148309NIAID NIH HHS U19 AI067773
6 · The paper itself

Abstract

In a nuclear or radiological incident, first responders must quickly and accurately measure radiation exposure among civilians as medical countermeasures are radiation dose-dependent and time-sensitive. Although several approaches have been explored to measure absorbed radiation dose, there is an important need to develop point-of-care (POC) bioassay devices that can be used immediately to triage thousands of individuals potentially exposed to radiation. Here we present a proof-of-concept study showing the use of a paper-based vertical flow immunoassay (VFI) to detect radiation dosimetry genes. Using labeled primers during amplification and a multiplex membrane, our results showed that the nucleic acid VFI can simultaneously detect two biodosimetry genes, CDKN1A and DDB2, as well as one housekeeping gene MRPS5. The assay demonstrated good linearity and precision with an inter- and intra-assay coefficient of variance <20% and <10%, respectively. Moreover, the assay showed its ability to discriminate non-irradiated controls (0 Gy) from irradiated samples (1 + 2 Gy) with an overall sensitivity of 62.5% and specificity of 100% (AUC = 0.8672, 95% CI: 0.723-1.000; p = 0.004). Interestingly, the gene combination also showed a dose-dependent response for 0, 1, and 2 Gy, similar to data obtained by real-time PCR benchmark. These preliminary results suggest that a VFI platform can be used to detect simultaneously multiple genes that can be then quantified, thus offering a new approach for a POC biodosimetry assay that could be rapidly deployed on-site to test a large population and help triage and medical management after radiological event.

Indexed as

Point-of-Care SystemsRadiometryGenes, EssentialHumansImmunoassayBiodosimetryGenePoint-of-care deviceRadiationVertical flow immunoassay

Identifiers

PMID37369178
PMCPMC10751381

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.