Evidence map›Paper›PMID 37368110›Full record

ArticleEuropean radiology2023

A CT-based predictive model for stent-induced vessel damage: application to type B aortic dissection.

Xuehuan Zhang, Dianpeng Wang, Xuyang Zhang, Shichao Liang, Ziheng Wu, Zipeng Wen, Yiannis Ventikos, Jiang Xiong, Duanduan Chen

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xuehuan ZhangSchool of Life Science, Beijing Institute of Technology, Beijing, China.
Dianpeng WangSchool of Mathematics, Beijing Institute of Technology, Beijing, China.
Xuyang ZhangSchool of Life Science, Beijing Institute of Technology, Beijing, China.
Shichao LiangSchool of Life Science, Beijing Institute of Technology, Beijing, China.
Ziheng WuDepartment of Vascular Surgery, First Affiliated Hospital of Medical College, Zhejiang University, Zhejiang, China.
Zipeng WenThe High School Affiliated to Renmin University of China, Beijing, China.
Yiannis VentikosSchool of Life Science, Beijing Institute of Technology, Beijing, China.
Jiang XiongDepartment of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China. xiongjiangdoc@126.com.
Duanduan ChenSchool of Medical Technology, Beijing Institute of Technology, Beijing, China. duanduan@bit.edu.cn.ORCID http://orcid.org/0000-0002-5706-4369

Funding

Innovative Research Group Project of the National Natural Science Foundation of China 81770465Innovative Research Group Project of the National Natural Science Foundation of China 81970404Key R&D Program of Zhejiang Province 2019C03013National Key R&D Program of China 2018AAA0102600Natural Science Foundation of Beijing Municipality L192010Natural Science Foundation of Beijing Municipality L192045Natural Science Foundation of Beijing Municipality Z190014
6 · The paper itself

Abstract

objectivesThe distal stent-induced new entry (distal SINE) is a life-threatening device-related complication after thoracic endovascular aortic repair (TEVAR). However, risk factors for distal SINE are not fully determined, and prediction models are lacking. This study aimed to establish a predictive model for distal SINE based on the preoperative dataset.

methodsTwo hundred and six patients with Stanford type B aortic dissection (TBAD) that experienced TEVAR were involved in this study. Among them, thirty patients developed distal SINE. Pre-TEVAR morphological parameters were measured based on the CT-reconstructed configurations. Virtual post-TEVAR morphological and mechanical parameters were computed via the virtual stenting algorithm (VSA). Two predictive models (PM-1 and PM-2) were developed and presented as nomograms to help risk evaluation of distal SINE. The performance of the proposed predictive models was evaluated and internal validation was conducted.

resultsMachine-selected variables for PM-1 included key pre-TEVAR parameters, and those for PM-2 included key virtual post-TEVAR parameters. Both models showed good calibration in both development and validation subsamples, while PM-2 outperformed PM-1. The discrimination of PM-2 was better than PM-1 in the development subsample, with an optimism-corrected area under the curve (AUC) of 0.95 and 0.77, respectively. Application of PM-2 in the validation subsample presented good discrimination with an AUC of 0.9727. The decision curve demonstrated that PM-2 was clinically useful.

conclusionThis study proposed a predictive model for distal SINE incorporating the CT-based VSA. This predictive model could efficiently predict the risk of distal SINE and thus might contribute to personalized intervention planning. CLINICAL RELEVANCE STATEMENT: This study established a predictive model to evaluate the risk of distal SINE based on the pre-stenting CT dataset and planned device information. With an accurate VSA tool, the predictive model could help to improve the safety of the endovascular repair procedure. KEY POINTS: • Clinically useful prediction models for distal stent-induced new entry are still lacking, and the safety of the stent implantation is hard to guarantee. • Our proposed predictive tool based on a virtual stenting algorithm supports different stenting planning rehearsals and real-time risk evaluation, guiding clinicians to optimize the presurgical plan when necessary. • The established prediction model provides accurate risk evaluation for vessel damage, improving the safety of the intervention procedure.

Indexed as

Aortic Aneurysm, ThoracicAortic DissectionBlood Vessel Prosthesis ImplantationEndovascular ProceduresBlood Vessel ProsthesisHumansIncidencePostoperative ComplicationsRetrospective StudiesRisk FactorsStentsTomography, X-Ray ComputedTreatment OutcomeAortic dissectionComputer simulationPostoperative complicationsPredictive medicineThoracic endovascular aortic repair

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked