Evidence map›Paper›PMID 37367466›Full record

ArticleJournal of imaging2023

Short-Term Precision and Repeatability of Radiofrequency Echographic Multi Spectrometry (REMS) on Lumbar Spine and Proximal Femur: An In Vivo Study.

Carmelo Messina, Salvatore Gitto, Roberta Colombo, Stefano Fusco, Giada Guagliardo, Mattia Piazza, Jacopo Carlo Poli, Domenico Albano, Luca Maria Sconfienza

Open access · goldAbstract read
In one paragraph

Article in Journal of imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Review
  6. Article
  7. In Vivo Assessment of Bone Quality Without X-rays.Current osteoporosis reports · 2024
    Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Carmelo MessinaIRCCS Istituto Ortopedico Galeazzi, Via Cristina Belgioioso, 173, 20157 Milan, Italy.
Salvatore GittoIRCCS Istituto Ortopedico Galeazzi, Via Cristina Belgioioso, 173, 20157 Milan, Italy.ORCID 0000-0002-3623-7822
Roberta ColomboIRCCS Istituto Ortopedico Galeazzi, Via Cristina Belgioioso, 173, 20157 Milan, Italy.
Stefano FuscoScuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono, 7, 20122 Milan, Italy.
Giada GuagliardoScuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono, 7, 20122 Milan, Italy.
Mattia PiazzaScuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono, 7, 20122 Milan, Italy.
Jacopo Carlo PoliScuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono, 7, 20122 Milan, Italy.
Domenico AlbanoIRCCS Istituto Ortopedico Galeazzi, Via Cristina Belgioioso, 173, 20157 Milan, Italy.ORCID 0000-0001-7989-9861
Luca Maria SconfienzaIRCCS Istituto Ortopedico Galeazzi, Via Cristina Belgioioso, 173, 20157 Milan, Italy.
University of Milan · ITIstituto Ortopedico Galeazzi · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To determine the short-term intra-operator precision and inter-operator repeatability of radiofrequency echographic multi-spectrometry (REMS) at the lumbar spine (LS) and proximal femur (FEM). All patients underwent an ultrasound scan of the LS and FEM. Both precision and repeatability, expressed as root-mean-square coefficient of variation (RMS-CV) and least significant change (LSC) were obtained using data from two consecutive REMS acquisitions by the same operator or two different operators, respectively. The precision was also assessed in the cohort stratified according to BMI classification. The mean (±SD) age of our subjects was 48.9 ± 6.8 for LS and 48.3 ± 6.1 for FEM. Precision was assessed on 42 subjects at LS and 37 subjects on FEM. Mean (±SD) BMI was 24.71 ± 4.2 for LS and 25.0 ± 4.84 for FEM. Respectively, the intra-operator precision error (RMS-CV) and LSC resulted in 0.47% and 1.29% at the spine and 0.32% and 0.89% at the proximal femur evaluation. The inter-operator variability investigated at the LS yielded an RMS-CV error of 0.55% and LSC of 1.52%, whereas for the FEM, the RMS-CV was 0.51% and the LSC was 1.40%. Similar values were found when subjects were divided into BMI subgroups. REMS technique provides a precise estimation of the US-BMD independent of subjects' BMI differences.

Indexed as

Body Mass Index (BMI)Bone Mineral Density (BMD)precisionRadiofrequency Echographic Multi Spectrometry (REMS)reproducibility

Identifiers

PMID37367466
PMCPMC10300972
OpenAlexW4380324353

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.