Evidence map›Paper›PMID 37366850›Full record

ArticleBiomimetics (Basel, Switzerland)2023

A 3D Printed, Bionic Hand Powered by EMG Signals and Controlled by an Online Neural Network.

Karla Avilés-Mendoza, Neil George Gaibor-León, Víctor Asanza, Leandro L Lorente-Leyva, Diego H Peluffo-Ordóñez

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Karla Avilés-MendozaNeuroimaging and Bioengineering Laboratory (LNB), Facultad de Ingeniería en Mecánica y Ciencias de la Producción, Escuela Superior Politécnica del Litoral (ESPOL), Campus Gustavo Galindo km 30.5 Vía Perimetral, Guayaquil 090903, Ecuador.ORCID 0000-0002-4644-4841
Neil George Gaibor-LeónNeuroimaging and Bioengineering Laboratory (LNB), Facultad de Ingeniería en Mecánica y Ciencias de la Producción, Escuela Superior Politécnica del Litoral (ESPOL), Campus Gustavo Galindo km 30.5 Vía Perimetral, Guayaquil 090903, Ecuador.ORCID 0000-0001-6827-652X
Víctor AsanzaSDAS Research Group, Ben Guerir 43150, Morocco.ORCID 0000-0002-2786-4162
Leandro L Lorente-LeyvaSDAS Research Group, Ben Guerir 43150, Morocco.ORCID 0000-0002-2973-7765
Diego H Peluffo-OrdóñezSDAS Research Group, Ben Guerir 43150, Morocco.ORCID 0000-0002-9045-6997

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

About 8% of the Ecuadorian population suffers some type of amputation of upper or lower limbs. Due to the high cost of a prosthesis and the fact that the salary of an average worker in the country reached 248 USD in August 2021, they experience a great labor disadvantage and only 17% of them are employed. Thanks to advances in 3D printing and the accessibility of bioelectric sensors, it is now possible to create economically accessible proposals. This work proposes the design of a hand prosthesis that uses electromyography (EMG) signals and neural networks for real-time control. The integrated system has a mechanical and electronic design, and the latter integrates artificial intelligence for control. To train the algorithm, an experimental methodology was developed to record muscle activity in upper extremities associated with specific tasks, using three EMG surface sensors. These data were used to train a five-layer neural network. the trained model was compressed and exported using TensorflowLite. The prosthesis consisted of a gripper and a pivot base, which were designed in Fusion 360 considering the movement restrictions and the maximum loads. It was actuated in real time thanks to the design of an electronic circuit that used an ESP32 development board, which was responsible for recording, processing and classifying the EMG signals associated with a motor intention, and to actuate the hand prosthesis. As a result of this work, a database with 60 electromyographic activity records from three tasks was released. The classification algorithm was able to detect the three muscle tasks with an accuracy of 78.67% and a response time of 80 ms. Finally, the 3D printed prosthesis was able to support a weight of 500 g with a safety factor equal to 15.

Indexed as

artificial intelligencebionic handelectromyographyneural networkreal-time classification

Identifiers

PMID37366850
PMCPMC10296662

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.