Evidence map›Paper›PMID 37366839›Full record

ArticleBiomimetics (Basel, Switzerland)2023

Finger Kinematics during Human Hand Grip and Release.

Xiaodong Li, Rongwei Wen, Dehao Duanmu, Wei Huang, Kinto Wan, Yong Hu

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Training Movement Velocity Significantly Affects the Performance of Myoelectric Control.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2025
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiaodong LiShenzhen Institute of Research and Innovation, The University of Hong Kong, Shenzhen 518057, China.
Rongwei WenShenzhen Institute of Research and Innovation, The University of Hong Kong, Shenzhen 518057, China.ORCID 0000-0002-5585-7824
Dehao DuanmuShenzhen Institute of Research and Innovation, The University of Hong Kong, Shenzhen 518057, China.ORCID 0000-0002-9227-1945
Wei HuangDepartment of Rehabilitation, The Second Affiliated Hospital of Guangzhou Medical University, Zhanjiang 524002, China.
Kinto WanDepartment of Orthopaedics and Traumatology, The University of Hong Kong, Hong Kong, China.
Yong HuShenzhen Institute of Research and Innovation, The University of Hong Kong, Shenzhen 518057, China.ORCID 0000-0003-0305-5616

Funding

National Key Research and Development Program of China 2021YFF0501600Shenzhen Local Science and Technology Development Fund guided by Central Government of China 2021Szvup130Zhanjiang Competitive allocation of special funds for scientific and technological development 2022A703-3
6 · The paper itself

Abstract

A bionic robotic hand can perform many movements similar to a human hand. However, there is still a significant gap in manipulation between robot and human hands. It is necessary to understand the finger kinematics and motion patterns of human hands to improve the performance of robotic hands. This study aimed to comprehensively investigate normal hand motion patterns by evaluating the kinematics of hand grip and release in healthy individuals. The data corresponding to rapid grip and release were collected from the dominant hands of 22 healthy people by sensory glove. The kinematics of 14 finger joints were analyzed, including the dynamic range of motion (ROM), peak velocity, joint sequence and finger sequence. The results show that the proximal interphalangeal (PIP) joint had a larger dynamic ROM than metacarpophalangeal (MCP) and distal interphalangeal (DIP) joints. Additionally, the PIP joint had the highest peak velocity, both in flexion and extension. For joint sequence, the PIP joint moved prior to the DIP or MCP joints during flexion, while extension started in DIP or MCP joints, followed by the PIP joint. Regarding the finger sequence, the thumb started to move before the four fingers, and stopped moving after the fingers during both grip and release. This study explored the normal motion patterns in hand grip and release, which provided a kinematic reference for the design of robotic hands and thus contributes to its development.

Indexed as

bio-inspiredfinger kinematicsgrasping and releasemotion coordinationrobotic hand

Identifiers

PMID37366839
PMCPMC10296280

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.