Evidence map›Paper›PMID 37366671›Full record

ArticleDentistry journal2023

SEM Evaluation of Thermal Effects Produced by a 445 nm Laser on Implant Surfaces.

Daniele Pergolini, Gaspare Palaia, Riccardo De Angelis, Federica Rocchetti, Gian Marco Podda, Gianluca Tenore, Alessandro Del Vecchio, Michela Relucenti, Umberto Romeo

Open access · goldAbstract read
In one paragraph

Article in Dentistry journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 4 citations in OpenAlex.

  1. Efficacy of a 445 nm wavelength laser in the surgical treatment of chronic otitis media.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Daniele PergoliniDepartment of Oral Sciences and Maxillofacial Surgery, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.ORCID 0000-0001-8885-0496
Gaspare PalaiaDepartment of Oral Sciences and Maxillofacial Surgery, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.ORCID 0000-0001-8509-2255
Riccardo De AngelisDepartment of Oral Sciences and Maxillofacial Surgery, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.ORCID 0000-0002-7084-1257
Federica RocchettiDepartment of Oral Sciences and Maxillofacial Surgery, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.
Gian Marco PoddaDepartment of Oral Sciences and Maxillofacial Surgery, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.ORCID 0000-0002-4981-5396
Gianluca TenoreDepartment of Oral Sciences and Maxillofacial Surgery, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.ORCID 0000-0001-9963-8052
Alessandro Del VecchioDepartment of Oral Sciences and Maxillofacial Surgery, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.
Michela RelucentiDepartment of Anatomical, Histological, Forensic and Orthopedic Sciences, Section of Human Anatomy, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.ORCID 0000-0002-3805-9505
Umberto RomeoDepartment of Oral Sciences and Maxillofacial Surgery, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.ORCID 0000-0003-2439-2187
Sapienza University of Rome · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this in vitro study was to evaluate thermal effects on implant surfaces using a 445 nm diode laser (Eltech K-Laser Srl, Treviso, Italy) with different power settings and irradiation modalities. Fifteen new implants (Straumann, Basel, Switzerland) were irradiated to evaluate surface alteration. Each implant was divided into two zones: the anterior and posterior areas. The anterior coronal areas were irradiated with a distance of 1 mm between the optical fiber and the implant; the anterior apical ones were irradiated with the fiber in contact with the implant. Instead, the posterior surfaces of all of the implants were not irradiated and used as control surfaces. The protocol comprised two cycles of laser irradiation, lasting 30 s each, with a one-minute pause between them. Different power settings were tested: a 0.5 W pulsed beam (T-on 25 ms; T-off 25 ms), a 2 W continuous beam and a 3 W continuous beam. Lastly, through a scanning electron microscopy (SEM) analysis, dental implants' surfaces were evaluated to investigate surface alterations. No surface alterations were detected using a 0.5 W laser beam with a pulsed mode at a distance of 1 mm. Using powers of irradiation of 2 W and 3 W with a continuous mode at 1 mm from the implant caused damage on the titanium surfaces. After the irradiation protocol was changed to using the fiber in contact with the implant, the surface alterations increased highly compared to the non-contact irradiation modality. The SEM results suggest that a power of irradiation of 0.5 W with a pulsed laser light emission mode, using an inactivated optical fiber placed 1 mm away from the implant, could be used in the treatment of peri-implantitis, since no implant surface alterations were detected.

Indexed as

dental implantslaserperi-implantitisthermal damage

Identifiers

PMID37366671
PMCPMC10297349
OpenAlexW4379882327

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials