Evidence map›Paper›PMID 37363840›Full record

ArticleIEEE transactions on biomedical circuits and systems2023

A Flexible Implant for Multi-Day Monitoring of Colon Segment Activity.

Steve J A Majerus, Dario Cabal, Yaneev Hacohen, Brett Hanzlicek, Aref Smiley, Yushan Wang, Wentai Liu, Muriel Larauche, Mulugeta Million, Margot S Damaser and 1 more

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on biomedical circuits and systems, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 6 institutions in 1 country.

Steve J A Majerus
Dario Cabal
Yaneev Hacohen
Brett Hanzlicek
Aref Smiley
Yushan Wang
Wentai Liu
Muriel Larauche
Mulugeta Million
Margot S Damaser
Dennis J Bourbeau
Louis Stokes Cleveland VA Medical Center · USCalifornia NanoSystems Institute · USCenter for Digestive and Liver Diseases · USCleveland Clinic Lerner College of Medicine · USCase Western Reserve University · USMetroHealth · US

Funding

Comprehensive Structural and Functional Mapping of Mammalian Colonic Nervous SystemOT2OD024899 · OD · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI MULUGETA, MILLION, TACHE, YVETTE FRANCE · 2017 to 2021
$13.1M
Conscious ambulatory bladder monitoring to understand neural control of lower urinary tract functionOT2OD023873 · OD · CLEVELAND CLINIC LERNER COM-CWRU · PI BOURBEAU, DENNIS, DAMASER, MARGOT S. · 2017 to 2021
$4.0M
NIH HHS OT2 OD023873NIH HHS OT2 OD024899RRD VA IK6 RX003843
6 · The paper itself

Abstract

Monitoring of colon activity is currently limited to tethered systems like anorectal manometry. These systems have significant drawbacks, but fundamentally limit the observation time of colon activity, reducing the likelihood of detecting specific clinical events. While significant technological advancement has been directed to mobile sensor capsules, this work describes the development and feasibility of a stationary sensor for describing the coordinated activity between neighboring segments of the colon. Unlike wireless capsules, this device remains in position and measures propagating pressure waves and impedances between colon segments to describe activity and motility. This low-power, flexible, wireless sensor-the colon monitor to capture activity (ColoMOCA) was validated in situ and in vivo over seven days of implantation. The ColoMOCA diameter was similar to common endoscopes to allow for minimally invasive diagnostic placement. The ColoMOCA included two pressure sensors, and three impedance-sensing electrodes arranged to describe the differential pressures and motility between adjacent colon segments. To prevent damage after placement in the colon, the ColoMOCA was fabricated with a flexible polyimide circuit board and a silicone rubber housing. The resulting device was highly flexible and suitable for surgical attachment to the colon wall. In vivo testing performed in eleven animals demonstrated suitability of both short term (less than 3 hours) and 7-day implantations. Data collected wirelessly from animal experiments demonstrated the ColoMOCA described colon activity similarly to wired catheters and allowed untethered, conscious monitoring of organ behavior.

Indexed as

ColonProstheses and ImplantsAnimalsCathetersElectric ImpedanceElectrodes

Identifiers

PMID37363840
PMCPMC10732233
OpenAlexW4382119232

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.