Evidence map›Paper›PMID 37361332›Full record

ArticleJOR spine2023

Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines.

Celien A M Jacobs, Remco J P Doodkorte, S Amir Kamali, Abdelrahman M Abdelgawad, Samaneh Ghazanfari, Stefan Jockenhoevel, J J Chris Arts, Marianna A Tryfonidou, Björn P Meij, Keita Ito

Open access · goldAbstract read
In one paragraph

Article in JOR spine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Celien A M JacobsOrthopedic Biomechanics, Department of Biomedical Engineering Eindhoven University of Technology Eindhoven Noord-Brabant The Netherlands.ORCID https://orcid.org/0000-0003-1413-4010
Remco J P DoodkorteDepartment of Orthopedic Surgery, Research School CAPHRI Maastricht University Medical Center Maastricht Limburg The Netherlands.
S Amir KamaliDepartment of Clinical Sciences, Faculty of Veterinary Medicine Utrecht University Utrecht Utrecht The Netherlands.
Abdelrahman M AbdelgawadAachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering Maastricht University Geleen Limburg The Netherlands.
Samaneh GhazanfariAachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering Maastricht University Geleen Limburg The Netherlands.
Stefan JockenhoevelAachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering Maastricht University Geleen Limburg The Netherlands.
J J Chris ArtsOrthopedic Biomechanics, Department of Biomedical Engineering Eindhoven University of Technology Eindhoven Noord-Brabant The Netherlands.
Marianna A TryfonidouDepartment of Clinical Sciences, Faculty of Veterinary Medicine Utrecht University Utrecht Utrecht The Netherlands.ORCID https://orcid.org/0000-0002-2333-7162
Björn P MeijDepartment of Clinical Sciences, Faculty of Veterinary Medicine Utrecht University Utrecht Utrecht The Netherlands.
Keita ItoOrthopedic Biomechanics, Department of Biomedical Engineering Eindhoven University of Technology Eindhoven Noord-Brabant The Netherlands.ORCID https://orcid.org/0000-0002-7372-4072
Maastricht University · NLUniversity of Applied Sciences Utrecht · NLEindhoven University of Technology · NLMaastricht University Medical Centre · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Context: Cervical disc replacement (CDR) aims to restore motion of the treated level to reduce the risk of adjacent segment disease (ASD) compared with spinal fusion. However, first-generation articulating devices are unable to mimic the complex deformation kinematics of a natural disc. Thus, a biomimetic artificial intervertebral CDR (bioAID), containing a hydroxyethylmethacrylate (HEMA)-sodium methacrylate (NaMA) hydrogel core representing the nucleus pulposus, an ultra-high-molecular-weight-polyethylene fiber jacket as annulus fibrosus, and titanium endplates with pins for primary mechanical fixation, was developed. Purpose: To assess the initial biomechanical effect of the bioAID on the kinematic behavior of the canine spine, an ex vivo biomechanical study in 6-degrees-of-freedom was performed. Study Design: A canine cadaveric biomechanical study. Methods: Six cadaveric canine specimens (C3-C6) were tested in flexion-extension (FE), lateral bending (LB) axial rotation (AR) using a spine tester in three conditions: intact, after C4-C5 disc replacement with bioAID, and after C4-C5 interbody fusion. A hybrid protocol was used where first the intact spines were subjected to a pure moment of ±1 Nm, whereafter the treated spines were subjected to the full range of motion (ROM) of the intact condition. 3D segmental motions at all levels were measured while recording the reaction torsion. Biomechanical parameters studied included ROM, neutral zone (NZ), and intradiscal pressure (IDP) at the adjacent cranial level (C3-C4). Results: The bioAID retained the sigmoid shape of the moment-rotation curves with a NZ similar to the intact condition in LB and FE. Additionally, the normalized ROMs at the bioAID-treated level were statistically equivalent to intact during FE and AR while slightly decreased in LB. At the two adjacent levels, ROMs showed similar values for the intact compared to the bioAID for FE and AR and an increase in LB. In contrast, levels adjacent to the fused segment showed an increased motion in FE and LB as compensation for the loss of motion at the treated level. The IDP at the adjacent C3-C4 level after implantation of bioAID was close to intact values. After fusion, increased IDP was found compared with intact but did not reach statistical significance. Conclusion: This study indicates that the bioAID can mimic the kinematic behavior of the replaced intervertebral disc and preserves that for the adjacent levels better than fusion. As a result, CDR using the novel bioAID is a promising alternative treatment for replacing severely degenerated intervertebral discs.

Indexed as

biomechanicalbiomimetic artificial disccervical spinekinematicstotal disc replacement

Identifiers

PMID37361332
PMCPMC10285750
OpenAlexW4321498993

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.