ArticleJournal of cardiology cases2023
A method for successfully implanting an implantable cardioverter-defibrillator wrapped with an expanded polytetrafluoroethylene sheet in a patient with metal allergy.
Article in Journal of cardiology cases, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Implanting a gold-coated cardioverter-defibrillator as a solution to cardiac implantable device hypersensitivity: a case report.European heart journal. Case reports · 2025Article
- Extravascular implantable cardioverter-defibrillator implantation in a patient with nickel and cobalt allergies.HeartRhythm case reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Contact dermatitis is a severe complication of cardiac-device implantation that may be observed in patients with metal allergies. Some studies have suggested that wrapping cardiac devices with expanded polytetrafluoroethylene (ePTFE) sheets is effective in preventing contact dermatitis. Most of these studies involved pacemakers, whereas those on implantable cardioverter-defibrillators (ICDs) are rare. Herein, we report a method for the successful implantation of an ICD wrapped with an ePTFE sheet in a patient with metal allergy. The metal part of the ICD generator was tightly wrapped with an ePTFE sheet, which was sewn with ePTFE sutures approximating the edges of the generator. After the wrapping procedure, the patient entered the operating room, and the generator and an ePTFE-coated dual-coil shock lead were implanted via a standard procedure. The shock impedance in the coil-to-can vector was high immediately after the implantation, but it reduced to less than half of its initial value over a period of two weeks post-surgery. The patient did not develop any new skin problems during the 20-month follow-up. This is a method for successfully preventing contact dermatitis; however, attention to the associated high risk of infection is required. Learning objective: Wrapping an implantable cardioverter-defibrillator with an expanded polytetrafluoroethylene sheet was effective in preventing contact dermatitis after implantation. The shock impedance in the coil-to-can vector was high immediately after implantation but reduced to approximately half of its initial value with time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.