ArticleJournal of cardiology cases2023

A method for successfully implanting an implantable cardioverter-defibrillator wrapped with an expanded polytetrafluoroethylene sheet in a patient with metal allergy.

Kei Morishita, Akiko Ishihara, Takatoshi Unno, Takahiko Murakami, Kensuke Okada, Hiroshi Matsunaga, Kazuo Asada, Yasutoshi Omori, Yoshiro Kamoi, Takahiro Tanaka

Abstract readCase Reports
In one paragraph

Article in Journal of cardiology cases, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kei MorishitaDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Akiko IshiharaDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Takatoshi UnnoDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Takahiko MurakamiDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Kensuke OkadaDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Hiroshi MatsunagaDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Kazuo AsadaDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Yasutoshi OmoriDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Yoshiro KamoiDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.
Takahiro TanakaDepartment of Cardiology, Showa General Hospital, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Contact dermatitis is a severe complication of cardiac-device implantation that may be observed in patients with metal allergies. Some studies have suggested that wrapping cardiac devices with expanded polytetrafluoroethylene (ePTFE) sheets is effective in preventing contact dermatitis. Most of these studies involved pacemakers, whereas those on implantable cardioverter-defibrillators (ICDs) are rare. Herein, we report a method for the successful implantation of an ICD wrapped with an ePTFE sheet in a patient with metal allergy. The metal part of the ICD generator was tightly wrapped with an ePTFE sheet, which was sewn with ePTFE sutures approximating the edges of the generator. After the wrapping procedure, the patient entered the operating room, and the generator and an ePTFE-coated dual-coil shock lead were implanted via a standard procedure. The shock impedance in the coil-to-can vector was high immediately after the implantation, but it reduced to less than half of its initial value over a period of two weeks post-surgery. The patient did not develop any new skin problems during the 20-month follow-up. This is a method for successfully preventing contact dermatitis; however, attention to the associated high risk of infection is required. Learning objective: Wrapping an implantable cardioverter-defibrillator with an expanded polytetrafluoroethylene sheet was effective in preventing contact dermatitis after implantation. The shock impedance in the coil-to-can vector was high immediately after implantation but reduced to approximately half of its initial value with time.

Indexed as

Cardiac implantable electronic deviceCongenital long QT syndromeContact dermatitisShock impedanceTorsades de pointes

Identifiers

PMID37360834
PMCPMC10287996

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.