Evidence map›Paper›PMID 37359507›Full record

ArticleIndian journal of thoracic and cardiovascular surgery2023

Aortic valve replacement in small aortic root- Bi-leaflet mechanical valve is superior to a Mono-leaflet mechanical valve.

Venkatesa Kumar Anakaputhur Rajan, Ameya Kaskar, Sendur Selvam, Rahul Rao, Siddhant Mehra, Thiruthani Kumaran, Varun Shetty

Open access · bronzeAbstract read
In one paragraph

Article in Indian journal of thoracic and cardiovascular surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Venkatesa Kumar Anakaputhur Rajan#258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore, 560099 Karnataka India Department of Cardiothoracic Surgery, Narayana Institute of Cardiac Sciences, Narayana Health.ORCID 0000-0002-8807-501X
Ameya Kaskar#258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore, 560099 Karnataka India Department of Cardiothoracic Surgery, Narayana Institute of Cardiac Sciences, Narayana Health.
Sendur Selvam#258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore, 560099 Karnataka India Department of Cardiothoracic Surgery, Narayana Institute of Cardiac Sciences, Narayana Health.
Rahul Rao#258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore, 560099 Karnataka India Department of Cardiothoracic Surgery, Narayana Institute of Cardiac Sciences, Narayana Health.
Siddhant Mehra#258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore, 560099 Karnataka India Department of Cardiothoracic Surgery, Narayana Institute of Cardiac Sciences, Narayana Health.
Thiruthani Kumaran#258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore, 560099 Karnataka India Department of Cardiothoracic Surgery, Narayana Institute of Cardiac Sciences, Narayana Health.
Varun Shetty#258/A, Bommasandra Industrial Area, Anekal Taluk, Bangalore, 560099 Karnataka India Department of Cardiothoracic Surgery, Narayana Institute of Cardiac Sciences, Narayana Health.
Narayana Health · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Patient prosthetic mismatch is a serious but avoidable complication of surgical aortic valve replacement (SAVR) complicated by a small aortic annulus. This study aims to compare early and midterm outcomes following aortic valve replacement (AVR) with a mono-leaflet (ML) valve and a bi-leaflet (BL) valve in a small aortic root. Methods and selection: From January 1st, 2017 to December 31st, 2019, 98 patients diagnosed with small aortic root underwent isolated aortic valve replacement with either TTK Chitra valve (Mono-leaflet/ ML group) or St. Jude medical valve (Bi-leaflet/ BL group) of size 17/ 19 mm. Echocardiography was analyzed from medical records and telephonic follow-up. Results: Baseline parameters were comparable. The ML group had 42 patients and the BL group had 56 patients. Aortic cross-clamp time, the incidence of severe patient prosthetic mismatch ( Conclusion: We conclude that aortic valve replacement without any root widening procedure, using a small-sized mechanical valve provides acceptable early outcomes. Bi-leaflet mechanical valves provide better hemodynamics and survival percentage.

Indexed as

Aortic valve replacementPatient prosthetic mismatchSmall aortic annulusSmall mechanical valves aortic root enlargement

Identifiers

PMID37359507
PMCPMC10199289
OpenAlexW4377139759

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.