Evidence map›Paper›PMID 37358782›Full record

ArticlePhysical and engineering sciences in medicine2023

Evaluation and assessment of clique arrangements for the estimation of omnipolar electrograms in high density electrode arrays: an experimental animal model study.

Samuel Ruipérez-Campillo, Marina Crespo, Álvaro Tormos, Antonio Guill, Antonio Cebrián, Antonio Alberola, Jakob Heimer, Francisco J Chorro, José Millet, Francisco Castells

Abstract read
In one paragraph

Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Impact of Catheter Configuration on the Mapping of Atrial Fibrillation.Circulation. Arrhythmia and electrophysiology · 2026
    Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Samuel Ruipérez-CampilloITACA Institute, Universitat Politècnica de València, Valencia, Spain. saruicam@upv.edu.es.ORCID http://orcid.org/0000-0002-5425-4175
Marina CrespoITACA Institute, Universitat Politècnica de València, Valencia, Spain.ORCID http://orcid.org/0000-0002-2885-5364
Álvaro TormosITACA Institute, Universitat Politècnica de València, Valencia, Spain.
Antonio GuillITACA Institute, Universitat Politècnica de València, Valencia, Spain.ORCID http://orcid.org/0000-0001-8546-264X
Antonio CebriánITACA Institute, Universitat Politècnica de València, Valencia, Spain.ORCID http://orcid.org/0000-0003-0519-5284
Antonio AlberolaDepartamento de Fisiología, Universitat de València, Valencia, Spain.ORCID http://orcid.org/0000-0001-8531-4161
Jakob HeimerDepartment of Mathematics, Seminar for Statistics, Swiss Federal Institute of Technology (ETH), Zürich, Switzerland.ORCID http://orcid.org/0000-0003-3499-8801
Francisco J ChorroCentro de Investigación Biomédica en Red Enfermedades Cardiovascular (CIBERCV), Madrid, Spain.ORCID http://orcid.org/0000-0002-4613-5459
José MilletITACA Institute, Universitat Politècnica de València, Valencia, Spain.ORCID http://orcid.org/0000-0002-8879-003X
Francisco CastellsITACA Institute, Universitat Politècnica de València, Valencia, Spain.ORCID http://orcid.org/0000-0001-5044-3545

Funding

Instituto de Salud Carlos III CIBERCV CB16/11/0048Ministerio de Ciencia e Innovación PID2019-109547RB-I00
6 · The paper itself

Abstract

High-density catheters combined with Orientation Independent Sensing (OIS) methods have emerged as a groundbreaking technology for cardiac substrate characterisation. In this study, we aim to assess the arrangements and constraints to reliably estimate the so-called omnipolar electrogram (oEGM). Performance was evaluated using an experimental animal model. Thirty-eight recordings from nine retrospective experiments on isolated perfused rabbit hearts with an epicardial HD multielectrode were used. We estimated oEGMs according to the classic triangular clique (4 possible orientations) and a novel cross-orientation clique arrangement. Furthermore, we tested the effects of interelectrode spacing from 1 to 4 mm. Performance was evaluated by means of several parameters that measured amplitude rejection ratios, electric field loop area, activation pulse width and morphology distortion. Most reliable oEGM estimations were obtained with cross-configurations and interelectrode spacings [Formula: see text] mm. Estimations from triangular cliques resulted in wider electric field loops and unreliable detection of the direction of the propagation wavefront. Moreover, increasing interelectrode distance resulted in increased pulse width and morphology distortion. The results prove that current oEGM estimation techniques are insufficiently accurate. This study opens a new standpoint for the design of new-generation HD catheters and mapping software.

Indexed as

HeartSoftwareAnimalsElectrodesModels, AnimalRabbitsRetrospective StudiesCardiac cathetersExperimental animal studyHigh density electrode arraysLocal substrate explorationOmnipolar electrogramsSignal processing