Evidence map›Paper›PMID 37358492›Full record

ArticleTranslational vision science & technology2023

Suprathreshold Approaches to Mapping the Visual Field in Advanced Glaucoma.

Jonathan Denniss, Allison M McKendrick, Andrew Turpin

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Targeted perimetry for mapping the shape of glaucomatous arcuate scotomata.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2025
    Article
  3. Article
  4. Article
  5. Frequency-of-seeing curves (psychometric functions) for perimetric stimuli in age-related macular degeneration.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2025
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Jonathan DennissSchool of Optometry and Vision Science, University of Bradford, Bradford, UK.
Allison M McKendrickDepartment of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia.
Andrew TurpinLions Eye Institute, Nedlands, Western Australia, Australia.
Lions Eye Institute · AUUniversity of Bradford · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Measuring the spatial extent of defects may be advantageous in advanced glaucoma where conventional perimetric sensitivity measurements are unreliable. We test whether suprathreshold tests on a higher density grid can more efficiently map advanced visual field loss. Methods: Data from 97 patients with mean deviation < -10 dB were used in simulations comparing two suprathreshold procedures (on a high-density 1.5° grid) to interpolated Full Threshold 24-2. Spatial binary search (SpaBS) presented 20-dB stimuli at locations bisecting seen/unseen points until the seen status of all neighbors matched or until tested points were adjacent. The SupraThreshold Adaptive Mapping Procedure (STAMP) presented 20-dB stimuli where entropy was maximal and modified the status of all points after each presentation, stopping after a fixed number of presentations (estimated as 50%-100% of the presentation number of a current procedure). Results: With typical response errors, SpaBS had worse mean accuracy and repeatability than Full Threshold (both P < 0.0001). Compared to Full Threshold, mean accuracy (Full Threshold: median, 91%; interquartile range [IQR], 87%-94%) was slightly better with STAMP for all stopping criteria, although this was not statistically significant until 100% of conventional test presentations were used. Mean repeatability for STAMP was similar for all stopping criteria (P ≥ 0.02) compared to Full Threshold (Full Threshold: median, 89%; IQR, 82%-93%). Conclusions: STAMP accurately and repeatably maps the spatial extent of advanced visual field defects in as few as 50% of conventional perimetric test presentations. Further work is needed to test STAMP in human observers and in progressive loss. Translational Relevance: New perimetric approaches may improve information available for advanced glaucoma management and may potentially be more acceptable to patients.

Indexed as

GlaucomaVisual FieldsHumansReproducibility of ResultsSensitivity and SpecificitySensory ThresholdsVision DisordersVisual Field Tests

Identifiers

PMID37358492
PMCPMC10297785
OpenAlexW4382010957

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.