Evidence map›Paper›PMID 37357139›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2024

Implantable, Bioresorbable Radio Frequency Resonant Circuits for Magnetic Resonance Imaging.

Geumbee Lee, Mark D Does, Raudel Avila, Juyeon Kang, Kevin D Harkins, Yunyun Wu, William E Banks, Minsu Park, Di Lu, Xinqiang Yan and 10 more

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Environmental and Ecological Monitoring with Biodegradable Technologies.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  5. Bioresorbable Materials for Wound Management.Biomimetics (Basel, Switzerland) · 2025
    Review
  6. Article
  7. Review
  8. High-resolution awake mouse fMRI at 14 Tesla.bioRxiv : the preprint server for biology · 2024
    Article
  9. Implantable, Bioresorbable Radio Frequency Resonant Circuits for Magnetic Resonance Imaging.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors.

Geumbee LeeQuerrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA.ORCID 0000-0003-0907-4092
Mark D DoesDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37235, USA.ORCID 0000-0003-2701-6208
Raudel AvilaDepartment of Mechanical Engineering, Northwestern University, Evanston, IL, 60208, USA.
Juyeon KangDepartment of Chemical and Biomolecular Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.
Kevin D HarkinsVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.ORCID 0000-0003-3579-9273
Yunyun WuQuerrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA.
William E BanksDepartment of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37235, USA.
Minsu ParkQuerrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA.
Di LuSchool of Microelectronics, University of Science and Technology of China, Hefei, Anhui, 230026, China.
Xinqiang YanVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
Jong Uk KimQuerrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA.
Sang Min WonDepartment of Electrical and Computer Engineering, Sungkyunkwan University, 2066, Seobu-ro, Jangan-gu, Suwon-si, Gyeonggi-do, 16419, Republic of Korea.
Adam G EvansDepartment of Plastic Surgery, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
Jeremy T JosephDepartment of Plastic Surgery, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
Christopher L KalmarDepartment of Plastic Surgery, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
Alonda C PollinsDepartment of Plastic Surgery, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
Huseyin KaragozDepartment of Plastic Surgery, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
Wesley P ThayerDepartment of Plastic Surgery, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
Yonggang HuangDepartment of Mechanical Engineering, Northwestern University, Evanston, IL, 60208, USA.
John A RogersQuerrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA.ORCID 0000-0002-2980-3961

Funding

Bioresorbable RF Coils For Post-Surgical Monitoring by MRIR21EB027881 · NIBIB · VANDERBILT UNIVERSITY · PI DOES, MARK D · 2020 to 2021
$476k
Ford Foundation Predoctoral FellowshipNational Science Foundation Graduate Research Fellowship 1842165NIBIB NIH HHS R21 EB027881NIH HHSNorthwestern's MRSEC program NSF DMR-1720139SHyNE Resource NSF ECCS-2025633
6 · The paper itself

Abstract

Magnetic resonance imaging (MRI) is widely used in clinical care and medical research. The signal-to-noise ratio (SNR) in the measurement affects parameters that determine the diagnostic value of the image, such as the spatial resolution, contrast, and scan time. Surgically implanted radiofrequency coils can increase SNR of subsequent MRI studies of adjacent tissues. The resulting benefits in SNR are, however, balanced by significant risks associated with surgically removing these coils or with leaving them in place permanently. As an alternative, here the authors report classes of implantable inductor-capacitor circuits made entirely of bioresorbable organic and inorganic materials. Engineering choices for the designs of an inductor and a capacitor provide the ability to select the resonant frequency of the devices to meet MRI specifications (e.g., 200 MHz at 4.7 T MRI). Such devices enhance the SNR and improve the associated imaging capabilities. These simple, small bioelectronic systems function over clinically relevant time frames (up to 1 month) at physiological conditions and then disappear completely by natural mechanisms of bioresorption, thereby eliminating the need for surgical extraction. Imaging demonstrations in a nerve phantom and a human cadaver suggest that this technology has broad potential for post-surgical monitoring/evaluation of recovery processes.

Indexed as

Absorbable ImplantsMagnetic Resonance ImagingEquipment DesignHumansPhantoms, ImagingRadio WavesSignal-To-Noise Ratiobiomedical implantsbioresorbable devicesLC‐resonant circuitsmagnetic resonance imagingradiofrequency coils

Identifiers

PMID37357139
PMCPMC11251549

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.