ArticlePhysical and engineering sciences in medicine2023
Initial end-to-end testing of the ExacTrac dynamic deep inspiration breath hold workflow using a breath hold breast phantom.
Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Comparison of surface-guided radiotherapy-based deep inspiration breath hold and continuous positive airway pressure techniques in left-sided breast cancer: dosimetric and workflow analysis.Physical and engineering sciences in medicine · 2026Article
- Commissioning of a combined stereoscopic x-ray and surface guided radiotherapy system for performing breath hold gated lung radiotherapy.Journal of applied clinical medical physics · 2025Article
- Integrating surface-guided radiation therapy and continuous positive airway pressure for breast cancer: Improving reproducibility and efficacy.Journal of applied clinical medical physics · 2025Article
- Use of surface tracking recordings to identify pitfalls during surface-guided radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025Article
- Optimizing Computed Tomography-derived Surface Monitoring for Accurate Cancer Radiotherapy Setup.In vivo (Athens, Greece)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
ExacTrac Dynamic (ETD) provides a Deep Inspiration Breath Hold (DIBH) workflow for breast patients. Stereoscopic x-ray imaging combined with optical and thermal mapping allows localisation against simulation imaging, alongside surface guided breath hold monitoring. This work aimed to determine appropriate imaging parameters, the optimal Hounsfield Unit (HU) threshold for patient contour generation and workflow evaluation via end-to-end (E2E) positioning using a custom breast DIBH phantom. After localisation via existing Image Guidance (IG), stereoscopic imaging was performed with a range of parameters to determine best agreement. Similarly, residual errors in prepositioning were minimised using a range of HU threshold contours. E2E positioning was completed for clinical workflows allowing residual isocentre position error measurement and existing IG comparison. Parameters of 60 kV and 25mAs were determined appropriate for patient imaging and HU thresholds between -600 HU and -200 HU enabled adequate prepositioning. The average and standard deviation in residual isocentre position error was 1.0 ± 0.9 mm, 0.4 ± 1.0 mm and 0.1 ± 0.5 mm in the lateral, longitudinal and vertical directions, respectively. Errors measured using existing IG were -0.6 ± 1.1 mm, 0.5 ± 0.7 mm and 0.2 ± 0.4 mm in the lateral, longitudinal and vertical directions, and 0.0 ± 1.0