ReviewAnnals of plastic surgery2023
The Keller Funnel, Capsular Contracture, and Conflict of Interest: A Review.
Review in Annals of plastic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Breast implant insertion funnels for preventing capsular contracture.The Cochrane database of systematic reviews · 2026Pooled it
- The Use of Laparoscopic Camera Sleeve in Implant-Based Breast Reconstruction: An Innovative "No-Touch" Technique.Aesthetic plastic surgery · 2026Article
- Why pay more for robot in breast surgery: literature review and analysis of costs.Gland surgery · 2026Review
- Experience Using the Funnel Insertion Method Lubricated With Hyaluronic Acid for Breast Implantation.Plastic and reconstructive surgery. Global open · 2026Article
- The Keller Funnel, Handedness, and Reducing Complications After Breast Augmentation.Aesthetic plastic surgery · 2026Article
- Ensuring Equal Implantation Conditions on Both Sides During Breast Augmentation: Effective Decontamination of Implantation Funnels.Aesthetic plastic surgery · 2025Article
- A Review of Mammaplasties With Measurements: Evaluating Autoaugmentation, Mesh, Acellular Dermal Matrix, and the Wise Pattern.Annals of plastic surgery · 2025Review
- Conflict of Interest and Plastic Surgery Journal Editors: The Problem and the Solution.Annals of plastic surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe Keller funnel (Allergan; AbbVie Inc, North Chicago, IL) is commonly used to insert breast implants as part of a "no touch" protocol. Many plastic surgeons believe that this device reduces the risk of capsular contracture. This review was undertaken to evaluate the evidence regarding any reduction in capsular contracture rate, other possible benefits, safety and to investigate financial conflict of interest.
methodsA PubMed electronic literature search was conducted to identify studies comparing capsular contracture rates with and without the Keller funnel. The Open Payments database was accessed for information regarding corporate payments to plastic surgeons.
resultsTwo retrospective historical case-control studies, published in 2016 and 2018, were identified. Both studies had important confounders, including implant type and placement, which are known to affect capsular contracture rates. Major financial conflicts of interest were present. Most authors did not disclose these conflicts, which totaled more than $1 million and were usually categorized as gifts from Allergan, which purchased the Keller funnel in 2017. DISCUSSION: Financial conflict of interest, along with publication bias, creates a bias toward publication of positive findings. No reliable evidence supports a "no touch" technique, which is a misnomer because manual handling of implants is unavoidable, even when using a funnel. Recent microbiological studies do not support a specific bacterial etiology for capsular contracture. No evidence supports contamination by the surgeon touching the implant. Among other proposed benefits, such as reduced operating time, less contamination, a shorter incision, and less implant trauma, only a slightly shorter incision (1 cm) is supported by the evidence. The cost is $150 per funnel.
conclusionsNo reliable evidence supports the use of a Keller funnel to reduce the risk of capsular contracture. Both supportive studies contain confounding variables, limited follow-up time, and no plausible scientific basis for efficacy. Institutional review board approval of studies on human subjects is not optional. Financial conflicts of interest are extraordinary in their magnitude and potential for creating undue influence. Greater transparency and honest disclosures are needed.
Indexed as