ArticleScientific reports2023
Validation of collaborative cyberspace virtual reality oculometry enhanced with near real-time spatial audio.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Currently, most medical image data, such as optical coherence tomography (OCT) images, are displayed in two dimensions on a computer screen. Advances in computer information technology have contributed to the growing storage of these data in electronic form. However, the data are usually processed only locally on site. To overcome such hurdles, a cyberspace virtual reality (csVR) application was validated, in which interactive OCT data were presented simultaneously to geographically distant sites (Lucerne, London, and Barcelona) where three graders independently measured the ocular csVR OCT diameters. A total of 109 objects were measured, each three times, resulting in a total of 327 csVR measurements. A minor mean absolute difference of 5.3 µm was found among the 3 measurements of an object (standard deviation 4.2 µm, coefficient of variation 0.3% with respect to the mean object size). Despite the 5 h of online work, csVR was well tolerated and safe. Digital high-resolution OCT data can be remotely and collaboratively processed in csVR. With csVR, measurements and actions enhanced with spatial audio communication can be made consistently in near real time, even if the users are situated geographically far apart. The proposed visuo-auditory framework has the potential to further boost the convenience of digital medicine toward csVR precision and collaborative medicine.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.