ArticleAnalytical chemistry2023
Dynamic Energy Measurements in Charge Detection Mass Spectrometry Eliminate Adverse Effects of Ion-Ion Interactions.
Article in Analytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 10 citations in OpenAlex.
- Accurate Sizing and Resolution of Nominal 200 nm Diameter Polystyrene Nanospheres With Charge Detection Mass Spectrometry.Small (Weinheim an der Bergstrasse, Germany) · 2026Article
- Atmospheric Sampling Mass Spectrometers Activate and Ionize Neutral Water Microdroplets to MeV Energies and up to 200,000+ Charges: Implications for Water Stability and Unusual Chemistry in Microdroplets.ACS central science · 2025Article
- Spontaneous Fission of Charged Water Nanodrops: Unveiling the Stochastic Nature of Fission Pathways and Dynamics.Journal of the American Chemical Society · 2025Article
- Article
- Charge Detection Mass Spectrometry Reveals Conformational Heterogeneity in Megadalton-Sized Monoclonal Antibody Aggregates.Journal of the American Chemical Society · 2024Article
- Thermal Remodeling of Human HDL Particles Reveals Diverse Subspecies.Journal of the American Society for Mass Spectrometry · 2024Article
- Article
- Single-Ion Mass Spectrometry for Heterogeneous and High Molecular Weight Samples.Journal of the American Chemical Society · 2024Review
- Ion emission from 1-10 MDa salt clusters: individual charge state resolution with charge detection mass spectrometry.The Analyst · 2024Article
- Combined Multiharmonic Frequency Analysis for Improved Dynamic Energy Measurements and Accuracy in Charge Detection Mass Spectrometry.Analytical chemistry · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
Ion-ion interactions in charge detection mass spectrometers that use electrostatic traps to measure masses of individual ions have not been reported previously, although ion trajectory simulations have shown that these types of interactions affect ion energies and thereby degrade measurement performance. Here, examples of interactions between simultaneously trapped ions that have masses ranging from ca. 2 to 350 MDa and ca. 100 to 1000 charges are studied in detail using a dynamic measurement method that makes it possible to track the evolution of the mass, charge, and energy of individual ions over their trapping lifetimes. Signals from ions that have similar oscillation frequencies can have overlapping spectral leakage artifacts that result in slightly increased uncertainties in the mass determination, but these effects can be mitigated by the careful choice of parameters used in the short-time Fourier transform analysis. Energy transfers between physically interacting ions are also observed and quantified with individual ion energy measurement resolution as high as ∼950. The mass and charge of interacting ions do not change, and their corresponding measurement uncertainties are equivalent to ions that do not undergo physical interactions. Simultaneous trapping of multiple ions in CDMS can greatly decrease the acquisition time necessary to accumulate a statistically meaningful number of individual ion measurements. These results demonstrate that while ion-ion interactions can occur when multiple ions are trapped, they have negligible effects on mass accuracy when using the dynamic measurement method.
Identifiers
What OpenQuestion holds
Registered trials