Evidence map›Paper›PMID 37342685›Full record

ArticleBiomedical optics express2023

Spectral focusing-based stimulated Raman scattering microscopy using compact glass blocks for adjustable dispersion.

Justin R Gagnon, Christian Harry Allen, Dominique Trudel, Frederic Leblond, Peter K Stys, Craig Brideau, Sangeeta Murugkar

Abstract read
In one paragraph

Article in Biomedical optics express, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Lipid droplets as cell fate determinants in skeletal muscle.Trends in endocrinology and metabolism: TEM · 2025
    Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Justin R GagnonDepartment of Physics, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, K1S 5B6, Canada.
Christian Harry AllenDepartment of Physics, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, K1S 5B6, Canada.ORCID https://orcid.org/0000-0001-9025-3914
Dominique TrudelCentre de recherche du Centre hospitalier de l'Université de Montréal, Montreal, Quebec, Canada.
Frederic LeblondCentre de recherche du Centre hospitalier de l'Université de Montréal, Montreal, Quebec, Canada.
Peter K StysDepartment of Clinical Neurosciences, University of Calgary, 3330 Hospital Drive N.W. HRIC 1B37A, Calgary, Alberta, T2N 4N1, Canada.
Craig BrideauDepartment of Clinical Neurosciences, University of Calgary, 3330 Hospital Drive N.W. HRIC 1B37A, Calgary, Alberta, T2N 4N1, Canada.ORCID https://orcid.org/0000-0001-7992-0413
Sangeeta MurugkarDepartment of Physics, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, K1S 5B6, Canada.ORCID https://orcid.org/0000-0002-6350-4893

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Spectral focusing is a well-established technique for increasing spectral resolution in coherent Raman scattering microscopy. However, current methods for tuning optical chirp in setups using spectral focusing, such as glass rods, gratings, and prisms, are very cumbersome, time-consuming to use, and difficult to align, all of which limit more widespread use of the spectral focusing technique. Here, we report a stimulated Raman scattering (SRS) configuration which can rapidly tune optical chirp by utilizing compact adjustable-dispersion TIH53 glass blocks. By varying the height of the blocks, the number of bounces in the blocks and therefore path length of the pulses through the glass can be quickly modulated, allowing for a convenient method of adjusting chirp with almost no necessary realignment. To demonstrate the flexibility of this configuration, we characterize our system's signal-to-noise ratio and spectral resolution at different chirp values and perform imaging in both the carbon-hydrogen stretching region (MCF-7 cells) and fingerprint region (prostate cores). Our findings show that adjustable-dispersion glass blocks allow the user to effortlessly modify their optical system to suit their imaging requirements. These blocks can be used to significantly simplify and miniaturize experimental configurations utilizing spectral focusing.

Identifiers

PMID37342685
PMCPMC10278629

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.