Evidence map›Paper›PMID 37342596›Full record

ArticleJournal of medical physics

Rotational Set Up Uncertainly in Non-6D Couch and its Effects in Clinical Target Volume- Planning Target Volume Margin Calculation for Different Sites.

Ngangom Robert, Tinish Sehgal, Ranjit Singh, Arun Oinam, Gaurav Trivedi, Budhi Singh, Amit Bahl, Renu Madan, Bhavana Rai

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Setup and target volume shape variation in rectal cancer radiotherapy: a systematic literature review.Technical innovations & patient support in radiation oncology · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ngangom RobertDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Tinish SehgalDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Ranjit SinghDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Arun OinamDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Gaurav TrivediDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Budhi SinghDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Amit BahlDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Renu MadanDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Bhavana RaiDepartment of Radiotherapy and Oncology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purpose of this study was to estimate and incorporate rotational error to translational error for clinical target volume (CTV) to planning target volume (PTV) margin calculations for non-6D couch. Materials and Methods: The study involved cone-beam computed tomography (CBCT) images of the patients who already had treatment in Varian Trilogy Clinac. The different sites studied were brain (70 patients, 406 CBCT images), head and neck (72 patients, 356 CBCT images), pelvis (83 patients, 606 CBCT images), and breast (45 patients, 163 CBCT images). Rotational and translational patient shifts were measured with the help of Varian eclipse offline review. The rotational shift introduces translational shift as it resolved along craniocaudal and mediolateral directions. Both rotational and translational error follow normal distribution and their respective errors were used to calculate CTV-PTV margin using van Herk model. Results: Rotational effect on CTV-PTV margin contribution increases with increase in size of CTV. It also increases with increase in distance between center of mass of CTV and isocenter. These margins were more pronounce in single isocenter supraclavicular fossa-Tangential Breast plans. Conclusions: There is always rotational error in all sites and it causes shift and rotation of the target. Rotational contribution to the CTV-PTV margin depends upon geometric center of CTV and isocenter distance and also on size of CTV. CTV-PTV margins should incorporate rotational error along with transitional error.

Indexed as

Clinical target volume-planning target volume marginrotational uncertaintyset up errors

Identifiers

PMID37342596
PMCPMC10277305

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.