Evidence map›Paper›PMID 37342321›Full record

ArticleFrontiers in immunology2023

Multiplexed bead-based assay for the simultaneous quantification of human serum IgG antibodies to tetanus, diphtheria, pertussis toxin, filamentous hemagglutinin, and pertactin.

Vishal Rathod, Laxmikant Kadam, Manish Gautam, Prabhu Dasu Gumma, Kevin Marke, Cathy Asokanathan, Alex Douglas-Bardsley, Laura Hassell, Sachin Bhandare, Sumit Gupta and 6 more

Open access · goldAbstract read
In one paragraph

Article in Frontiers in immunology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 1 institution in 1 country.

Vishal RathodClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Laxmikant KadamClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Manish GautamClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Prabhu Dasu GummaClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Kevin MarkeScience, Research and Innovation, Medicines, and Healthcare Products Regulatory Agency, South Mimms, United Kingdom.
Cathy AsokanathanScience, Research and Innovation, Medicines, and Healthcare Products Regulatory Agency, South Mimms, United Kingdom.
Alex Douglas-BardsleyScience, Research and Innovation, Medicines, and Healthcare Products Regulatory Agency, South Mimms, United Kingdom.
Laura HassellScience, Research and Innovation, Medicines, and Healthcare Products Regulatory Agency, South Mimms, United Kingdom.
Sachin BhandareClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Sumit GuptaClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Sameer ParekhClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Pramod PujariClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Harish RaoClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Hitt SharmaClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Umesh ShaligramClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Sunil GairolaClinical Bioanalytical Laboratory, Serum Institute of India Pvt. Ltd., Pune, Maharashtra, India.
Serum Institute of India (India) · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Luminex bead-based assays offer multiplexing to test antibodies against multiple antigens simultaneously; however, this requires validation using internationally certified reference standards. Therefore, there is an urgent need to characterize existing reference standards for the standardization of multiplex immunoassays (MIAs). Here, we report the development and validation of an MIA for the simultaneous estimation of levels of human serum immunoglobulin G (IgG) antibodies for pertussis toxin (PT), filamentous hemagglutinin (FHA), pertactin (PRN), diphtheria toxoid (DT), and tetanus toxoid (TT). Methods: The MIA was assessed using a panel of human serum samples and WHO reference standards. The WHO reference standards were also studied for suitability in the MIA. Purified antigens (PT, FHA, PRN, DT, and TT) were coupled to the spectrally unique magnetic carboxylated microspheres. The method was validated in accordance with the United States Food and Drug Administration (US FDA), European Medicines Agency (EMA), and the International Committee of Harmonization Multidisciplinary (ICH M10) guidelines, and parameters such as precision, accuracy, dilutional linearity, assay range, robustness, and stability were assessed. Method agreements with commercially available IgG enzyme-linked immunosorbent assay (ELISA) assays were also evaluated. In addition, the study assessed the level of correlation between the IgG levels estimated by the MIA and the cell-based neutralizing antibody assays for PT and DT. Results: We identified that an equimix of WHO international standards (i.e., 06/142, 10/262, and TE-3) afforded the best dynamic range for all the antigens in the MIA. For all five antigens, we observed that the back-fitted recoveries using the four-parameter logistic (4-PL) regression fits ranged between 80% and 120% for all calibration levels, and the percentage coefficient of variation (% CV) was < 20%. In addition, the difference in mean fluorescence intensity (MFI) between the monoplex and multiplex format was < 10% for each antigen, indicating no crosstalk among the beads. The MIA also showed good agreement with conventional and commercially available assays, and a positive correlation (> 0.75) with toxin neutralization assays for PT and DT was observed. Conclusion: The MIA that was calibrated in accordance with WHO reference standards demonstrated increased sensitivity, reproducibility, and high throughput capabilities, allowing for the design of robust studies that evaluate both natural and vaccine-induced immunity.

Indexed as

DiphtheriaDiphtheria-Tetanus-acellular Pertussis VaccinesTetanusAntibodies, BacterialBacterial Outer Membrane ProteinsHemagglutininsHumansImmunoglobulin GPertussis ToxinReproducibility of ResultsUnited StatesVirulence Factors, BordetellaAntibodies, BacterialBacterial Outer Membrane ProteinsDiphtheria-Tetanus-acellular Pertussis VaccinesHemagglutininsImmunoglobulin GpertactinPertussis ToxinVirulence Factors, Bordetelladiphtheriaenzyme-linked immunosorbent assay (ELISA)Luminex (xMAP) methodmultiplex immunoassay (MIA)pertussistetanus

Identifiers

PMID37342321
PMCPMC10278353
OpenAlexW4379471835

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.