ArticleJAMA cardiology2023
Comparative Effectiveness of Percutaneous Microaxial Left Ventricular Assist Device vs Intra-Aortic Balloon Pump or No Mechanical Circulatory Support in Patients With Cardiogenic Shock.
Article in JAMA cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 40 citations in OpenAlex.
- Estimating the Effects of MTEER in U.S. Practice: A Transportability Analysis of the COAPT Trial.Journal of the American College of Cardiology · 2026Article
- Lower AKI Risk and Higher Survival With Microaxial Flow Pump Support During Elective PCI: A Propensity Score-Matched Study.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026Observational
- Way(s) Forward for Evidence Generation in Cardiogenic Shock.Circulation. Heart failure · 2026Article
- Evaluating Cardiovascular Devices Using Observational Analyses.Circulation · 2026Review
- Generalizability of Landmark Temporary MCS Device Trials: Insights From the CSWG Registry.JACC. Advances · 2026Article
- Pitfalls in Comparing Mechanical Circulatory Support Devices Using Administrative Datasets: Epidemiology of the Diseased Population.Journal of the Society for Cardiovascular Angiography & Interventions · 2025Article
- Safety and Efficacy of Percutaneous Ventricular Assist Device vs Intra-Aortic Balloon Pump in Elective High-Risk Percutaneous Coronary Intervention Procedures.Journal of the Society for Cardiovascular Angiography & Interventions · 2025Article
- Long-Term Outcomes Following Catheter-Based Therapies in Older Adults With Acute Pulmonary Embolism.JACC. Advances · 2025Article
- Combined Risk Stratification With Patient Characteristics and Biomarkers in Patients Treated With the Impella for Cardiogenic Shock.Journal of the American Heart Association · 2025Article
- Real-world interventional outcomes for cardiogenic shock complicating acute myocardial infarction.American heart journal plus : cardiology research and practice · 2025Article
- Mechanical circulatory support for complex, high-risk percutaneous coronary intervention.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025Review
- Clinical Review of Cardiogenic Shock After Acute Myocardial Infarction - Revascularization, Mechanical Circulatory Support, and Beyond.Circulation reports · 2025Review
- High-risk percutaneous coronary intervention in patients with reduced left ventricular ejection fraction deemed not suitable for surgical revascularisation. A clinical consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) in collaboration with the ESC Working Group on Cardiovascular Surgery.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025Article
- Comparison of Transcatheter Versus Surgical Tricuspid Repair Among Patients With Tricuspid Regurgitation: Two-Year Results.Circulation. Cardiovascular interventions · 2025Article
- Management of cardiogenic shock: state-of-the-art.Intensive care medicine · 2024Review
- Intra-aortic balloon pump is associated with the lowest whereas Impella with the highest inpatient mortality and complications regardless of severity or hospital types.Cardiovascular intervention and therapeutics · 2024Article
- Percutaneous Microaxial Ventricular Assist Device Versus Intra-Aortic Balloon Pump for Nonacute Myocardial Infarction Cardiogenic Shock.Journal of the American Heart Association · 2024Article
- Scrutinizing mechanical circulatory support in cardiogenic shock: Have we jumped the gun?Critical care (London, England) · 2024Article
- Treatment of Acute Myocardial Infarction and Cardiogenic Shock: Outcomes of the RECOVER III Postapproval Study by Society of Cardiovascular Angiography and Interventions Shock Stage.Journal of the American Heart Association · 2024Observational
- Changing Trends in Mechanical Circulatory Support Use and Outcomes in Patients Undergoing Percutaneous Coronary Interventions for Acute Coronary Syndrome Complicated With Cardiogenic Shock: Insights From a Nationwide Registry in Japan.Journal of the American Heart Association · 2023Article
Corrections and comments
- Commented on by
Authors and funding
11 authors at 5 institutions in 1 country.
Funding
Abstract
Importance: Recent studies have produced inconsistent findings regarding the outcomes of the percutaneous microaxial left ventricular assist device (LVAD) during acute myocardial infarction with cardiogenic shock (AMICS). Objective: To compare the percutaneous microaxial LVAD vs alternative treatments among patients presenting with AMICS using observational analyses of administrative data. Design, Setting, and Participants: This comparative effectiveness research study used Medicare fee-for-service claims of patients admitted with AMICS undergoing percutaneous coronary intervention from October 1, 2015, through December 31, 2019. Treatment strategies were compared using (1) inverse probability of treatment weighting to estimate the effect of different baseline treatments in the overall population; (2) instrumental variable analysis to determine the effectiveness of the percutaneous microaxial LVAD among patients whose treatment was influenced by cross-sectional institutional practice patterns; (3) an instrumented difference-in-differences analysis to determine the effectiveness of treatment among patients whose treatment was influenced by longitudinal changes in institutional practice patterns; and (4) a grace period approach to determine the effectiveness of initiating the percutaneous microaxial LVAD within 2 days of percutaneous coronary intervention. Analysis took place between March 2021 and December 2022. Interventions: Percutaneous microaxial LVAD vs alternative treatments (including medical therapy and intra-aortic balloon pump). Main Outcomes and Measures: Thirty-day all-cause mortality and readmissions. Results: Of 23 478 patients, 14 264 (60.8%) were male and the mean (SD) age was 73.9 (9.8) years. In the inverse probability of treatment weighting analysis and grace period approaches, treatment with percutaneous microaxial LVAD was associated with a higher risk-adjusted 30-day mortality (risk difference, 14.9%; 95% CI, 12.9%-17.0%). However, patients receiving the percutaneous microaxial LVAD had a higher frequency of factors associated with severe illness, suggesting possible confounding by measures of illness severity not available in the data. In the instrumental variable analysis, 30-day mortality was also higher with percutaneous microaxial LVAD, but patient and hospital characteristics differed across levels of the instrumental variable, suggesting possible confounding by unmeasured variables (risk difference, 13.5%; 95% CI, 3.9%-23.2%). In the instrumented difference-in-differences analysis, the association between the percutaneous microaxial LVAD and mortality was imprecise, and differences in trends in characteristics between hospitals with different percutaneous microaxial LVAD use suggested potential assumption violations. Conclusions: In observational analyses comparing the percutaneous microaxial LVAD to alternative treatments among patients with AMICS, the percutaneous microaxial LVAD was associated with worse outcomes in some analyses, while in other analyses, the association was too imprecise to draw meaningful conclusions. However, the distribution of patient and institutional characteristics between treatment groups or groups defined by institutional differences in treatment use, including changes in use over time, combined with clinical knowledge of illness severity factors not captured in the data, suggested violations of key assumptions that are needed for valid causal inference with different observational analyses. Randomized clinical trials of mechanical support devices will allow valid comparisons across candidate treatment strategies and help resolve ongoing controversies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.