Evidence map›Paper›PMID 37341893›Full record

ArticleJournal of ultrasound2024

Evaluation of skeletal muscle elasticity using color Doppler shear wave imaging.

Yuji Kanaya, Kei Konno, Yoshiki Yamakoshi, Nobuyuki Taniguchi, Hideaki Watanabe, Katsushi Takeshita

Open access · hybridAbstract read
In one paragraph

Article in Journal of ultrasound, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Yuji KanayaDepartment of Orthopaedic Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.ORCID http://orcid.org/0000-0002-9605-135X
Kei KonnoDepartment of Clinical Laboratory Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan. konnok@jichi.ac.jp.ORCID http://orcid.org/0000-0003-2785-3102
Yoshiki YamakoshiGunma University Graduate School of Science and Technology, Gunma University, 1-5-1 tenjin-cho, kiryu, Gunnma, 376-8515, Japan.ORCID http://orcid.org/0000-0002-1009-9812
Nobuyuki TaniguchiDepartment of Clinical Laboratory Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
Hideaki WatanabeDepartment of Orthopaedic Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
Katsushi TakeshitaDepartment of Orthopaedic Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.ORCID http://orcid.org/0000-0001-8470-4555
Jichi Medical University · JPGunma University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to (1) assess the precision and reproducibility of color Doppler shear wave imaging (CD SWI) by comparing it with shear wave elastography (SWE) via elasticity phantom measurements, and (2) investigate the potential clinical applications of CD SWI in the upper limb muscles by assessing the reproducibility of skeletal muscle elasticity evaluations.

methodsFour elastography phantoms of different stiffness (6.0-7.5 wt%) were used to assess the precision and reproducibility of CD SWI (compared with SWE) at depths. Typical upper limb muscles of 24 men were also assessed for this comparison.

resultsAt superficial depths (0-2 cm), the phantom measurements obtained using CD SWI and SWE were similar at all levels of stiffness. Furthermore, both methods were highly reliable, with almost perfect intra- and inter-operator reliabilities. At greater depths (2-4 cm), measurements obtained using both methods were similar at all stiffness levels. Although standard deviations (SDs) of the phantom measurements obtained using both methods at lower stiffness were similar, those at higher stiffness were different. The SD of the CD SWI measurements was < 50% of that of the SWE measurements. However, both methods were highly reliable in the phantom test, with almost perfect intra- and inter-operator reliabilities. The intra- and inter-operator reliabilities of the shear wave velocity measurements for typical muscles of the upper limbs were also substantial in clinical settings.

conclusionCD SWI is a valid method for measuring elasticity, with precision and reliability as high as those of SWE.

Indexed as

Elasticity Imaging TechniquesMuscle, SkeletalElasticityHumansMaleReproducibility of ResultsUltrasonographyColor Doppler shear wave imagingShear wave elastographySkeletal muscleTissue elasticity

Identifiers

PMID37341893
PMCPMC10908984
OpenAlexW4381469574

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.