Evidence map›Paper›PMID 37341036›Full record

ArticleMedical physics2023

Technical note: Multi-MATE, a high-throughput platform for automated image-guided small-animal irradiation.

Lu Jiang, Pavitra Ramesh, Ryan Neph, Ke Sheng

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Lu JiangDepartment of Radiation Oncology, University of California, Los Angeles, California, USA.
Pavitra RameshDepartment of Radiation Oncology, University of California, Los Angeles, California, USA.
Ryan NephDepartment of Radiation Oncology, University of California, Los Angeles, California, USA.
Ke ShengDepartment of Radiation Oncology, University of California, San Francisco, California, USA.
University of California, Los Angeles · USUniversity of California, San Francisco · US

Funding

UCLA Center for Biological RadioprotectorsU19AI067769 · NIAID · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI CHUTE, JOHN P, MCBRIDE, WILLIAM H. · 2005 to 2019
$44.6M
Development of A High Throughput Image-Guided IMRT System forPreclinical ResearchR01CA259008 · NCI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI SHENG, KE · 2021 to 2025
$2.3M
Robust IMPT with automated beam orientation and scanning spot optimizationR01CA230278 · NCI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI SHENG, KE · 2019 to 2023
$1.9M
Precision breast radiotherapy with the soft robot and supine CTR01EB031577 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI JIN, LIHUA, SHENG, KE · 2022 to 2025
$1.5M
NCI NIH HHS R01 CA230278NCI NIH HHS R01 CA259008NIAID NIH HHS U19 AI067769NIBIB NIH HHS R01 EB031577NIH HHS R01CA259008NIH HHS U19AI067769
6 · The paper itself

Abstract

backgroundSmall animal irradiation is essential to study the radiation response of new interventions before or parallel to human therapy. Image-guided radiotherapy (IGRT) and intensity-modulated radiotherapy (IMRT) are recently adopted in small animal irradiation to more closely mimic human treatments. However, sophisticated techniques require exceedingly high time, resources, and expertize that are often impractical. PURPOSE: We propose a high throughput and high precision platform named Multiple Mouse Automated Treatment Environment (Multi-MATE) to streamline image-guided small animal irradiation.

methodsMulti-MATE consists of six parallel and hexagonally arranged channels, each equipped with a transfer railing, a 3D-printed immobilization pod, and an electromagnetic control unit, computer-controlled via an Arduino interface. The mouse immobilization pods are transferred along the railings between the home position outside the radiation field and the imaging/irradiation position at the irradiator isocenter. All six immobilization pods are transferred to the isocenter in the proposed workflow for parallel CBCT scans and treatment planning. The immobilization pods are then sequentially transported to the imaging/therapy position for dose delivery. The positioning reproducibility of Multi-MATE are evaluated using CBCT and radiochromic films.

resultsWhile parallelizing and automating the image-guided small animal radiation delivery, Multi-MATE achieved the average pod position reproducibility of 0.17 ± 0.04 mm in the superior-inferior direction, 0.20 ± 0.04 mm in the left-right direction, and 0.12 ± 0.02mm in the anterior-posterior direction in repeated CBCT tests. Additionally, in image-guided dose delivery tasks, Multi-MATE demonstrated the positioning reproducibility of 0.17 ± 0.06 mm in the superior-inferior direction, 0.19 ± 0.06 mm in the left-right direction.

conclusionsWe designed, fabricated, and tested a novel automated irradiation platform, Multi-MATE to accelerate and automate image-guided small animal irradiation. The automated platform minimizes human operation and achieves high setup reproducibility and image-guided dose delivery accuracy. Multi-MATE thus removes a major barrier to implementing high-precision preclinical radiation research.

Indexed as

Radiotherapy, Image-GuidedAnimalsCone-Beam Computed TomographyMicePhantoms, ImagingRadiotherapy Planning, Computer-AssistedReproducibility of Results3D printingimmobilization deviceirradiation platformsmall-animal irradiation

Identifiers

PMID37341036
PMCPMC10733545
OpenAlexW4381470301

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.