Evidence map›Paper›PMID 37340954›Full record

ArticleRenal failure2023

An ultrasound-guided no incision banding method for the treatment of arteriovenous fistula high-flow in hemodialysis.

Yanan Wang, Jin Li, Wenjun Liu, Ying Zhang, Qing Li, Fan He

Open access · goldAbstract read
In one paragraph

Article in Renal failure, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Yanan WangDepartment of Nephrology, Tongji Hospital of Tongji medical college of Huazhong University of Science and Technology, Wuhan, China.
Jin LiDepartment of Nephrology, Tongji Hospital of Tongji medical college of Huazhong University of Science and Technology, Wuhan, China.
Wenjun LiuDepartment of Hematology and Nephropathy, Xishui People's Hospital, Huanggang City, China.
Ying ZhangDepartment of Nephrology, Tongji Hospital of Tongji medical college of Huazhong University of Science and Technology, Wuhan, China.
Qing LiDepartment of Nephrology, Tongji Hospital of Tongji medical college of Huazhong University of Science and Technology, Wuhan, China.
Fan HeDepartment of Nephrology, Tongji Hospital of Tongji medical college of Huazhong University of Science and Technology, Wuhan, China.ORCID 0000-0002-2487-5827
Tongji Hospital · CNArkana Laboratories · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveHigh-flow vascular access is one of the serious complications in the maturation and subsequent use of arteriovenous fistula (AVF). We adopted a novel surgical approach named no incision limited ligation indwelling needle assisted- revision (NILLINR) to treat high-flow of the hemodialysis vascular access and ascertained the outcomes by regular follow-up visits.

methodsThis is a retrospective study. 26 hemodialysis patients with symptomatic high-flow access (access flow > 1500 mL/min) were treated with the novel banding method without incision between June 2018 and October 2020. The flow of the brachial artery before and after the restriction was measured by experienced clinicians by using the duplex Doppler ultrasound (DUS). All 26 patients were followed up for up to 1 year. Meanwhile, the brachial artery flow was recorded at 6 months and 1 year after restriction.

resultsOf all 26 patients included in this study, the mean access flow volume decreased from 2196.2 ± 416.9 mL/min (mean ± SD) to 679.2 ± 67.1 mL/min immediately after the operation. During the follow-up, the volume flow of the brachial artery was still within the restricted range at 6 months (mean ± SD, 720.2 ± 164.7 mL/min) and 1 year (mean ± SD, 713.9 ± 173.8 mL/min) after the operation. Meanwhile, the mean duration of the operation is 8.5 ± 3.3 min, and there is no bleeding or rupture.

conclusionThis novel no-incision limited ligation indwelling needle-assisted revision is a safe, effective, and time-saving option to treat high-flow access.

Indexed as

Arteriovenous FistulaArteriovenous Shunt, SurgicalBlood Flow VelocityBrachial ArteryHumansRegional Blood FlowRenal DialysisRetrospective StudiesTreatment OutcomeUltrasonography, InterventionalVascular PatencyArteriovenous fistulahemodialysishigh-flow vascular accessno-incision banding method

Identifiers

PMID37340954
PMCPMC10286689
OpenAlexW4381469306

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.