Evidence map›Paper›PMID 37340049›Full record

ArticleScientific reports2023

Evaluation of immunoserological detection of anti-liver kidney microsomal, anti-soluble liver antigen and anti-mitochondrial antibodies.

Alejandro Campos-Murguia, Nicole Henjes, Stephanie Loges, Heiner Wedemeyer, Elmar Jaeckel, Richard Taubert, Bastian Engel

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. JHEP reports : innovation in hepatology · 2025
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 3 countries.

Alejandro Campos-MurguiaDepartment of Gastroenterology, Hepatology, Infectious Diseases and Endocrinology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
Nicole HenjesDepartment of Gastroenterology, Hepatology, Infectious Diseases and Endocrinology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
Stephanie LogesDepartment of Gastroenterology, Hepatology, Infectious Diseases and Endocrinology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
Heiner WedemeyerDepartment of Gastroenterology, Hepatology, Infectious Diseases and Endocrinology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
Elmar JaeckelDepartment of Gastroenterology, Hepatology, Infectious Diseases and Endocrinology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
Richard TaubertDepartment of Gastroenterology, Hepatology, Infectious Diseases and Endocrinology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
Bastian EngelDepartment of Gastroenterology, Hepatology, Infectious Diseases and Endocrinology, Hannover Medical School, Carl-Neuberg-Straße 1, 30625, Hannover, Germany. Engel.Bastian@mh-hannover.de.
Medizinische Hochschule Hannover · DEERN RARE-LIVER

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Autoantibodies are the diagnostic hallmark of autoimmune liver diseases. Indirect immunofluorescence (IFT) is the reference method for the detection of anti-mitochondrial antibodies (AMA) and anti-liver kidney microsomal type-1 (anti-LKM1) antibodies, and inhibition ELISA (iELISA) for anti-soluble liver antigen (anti-SLA) antibodies. Given the complexity of these techniques, commercial ELISAs have emerged as a practical alternative, but without head-to-head validations. This study evaluated the agreement between three commercial ELISAs and the reference techniques and the impact of polyreactive immunoglobulin G (pIgG), a recently described phenomenon in autoimmune hepatitis, on commercial ELISAs. Inter-rater reliability was assessed using Cohen-Kappa coefficient (κ). Forty-eight, 46, and 66 samples were analyzed for AMA, anti-LKM1, and anti-SLA, respectively. For AMA, one commercial assay showed high agreement (κ = 0.91 (0.78-1.00)) with the reference method, while the other two showed weak or moderate agreement. For anti-LKM1, only one commercial assay showed high agreement (κ = 0.86 (0.71-1.0)). For anti-SLA antibodies only moderate agreement was achieved (κ up to 0.71 (0.52-0.89)). There was a trend towards higher pIgG levels in false-positives in the commercial ELISAs. Patients with high suspicion of autoimmune liver diseases should be referred to reference laboratories with the capacity of performing gold standard methods if the initial ELISA-based screening was performed.

Indexed as

Hepatitis, AutoimmuneLiver DiseasesHumansKidneyMitochondriaReproducibility of Results

Identifiers

PMID37340049
PMCPMC10282044
OpenAlexW4381327687

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.