Evidence map›Paper›PMID 37339509›Full record

ArticleJournal of occupational and environmental hygiene2023

Validation of N95 respirator models for pressure drop and particle capture efficiency.

Patrick T O'Shaughnessy, Zoe Harris, Matthew Purdy, Ralph Altmaier

Abstract read
In one paragraph

Article in Journal of occupational and environmental hygiene, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Patrick T O'ShaughnessyDepartment of Occupational and Environmental Health, The University of Iowa, Iowa City, Iowa.
Zoe HarrisDepartment of Occupational and Environmental Health, The University of Iowa, Iowa City, Iowa.
Matthew PurdyDepartment of Occupational and Environmental Health, The University of Iowa, Iowa City, Iowa.
Ralph AltmaierDepartment of Occupational and Environmental Health, The University of Iowa, Iowa City, Iowa.

Funding

Pulmonary Toxicology Facility CoreP30ES005605 · NIEHS · UNIVERSITY OF IOWA · PI Brandi Janssen · 1990 to 2026
$40.5M
The Heartland Center for Occupational Health and Safety Education and Research CenterT42OH008491 · OH · UNIVERSITY OF IOWA · PI O'SHAUGHNESSY, PATRICK T · 2005 to 2025
$31.7M
ACL HHS T42OH008491NIEHS NIH HHS P30 ES005605NIOSH CDC HHS T42 OH008491
6 · The paper itself

Abstract

Despite efforts to apply administrative and engineering controls to minimize worker exposure to aerosols, filtering facepiece respirators (FFRs) continue to be an important form of personal protective equipment in hard-to-control settings such as healthcare, agriculture, and construction. Optimizing the performance of FFRs can be advanced with the use of mathematical models that incorporate the forces that act on particles during filtration as well as those filter characteristics that influence filter pressure drop. However, a thorough investigation of these forces and characteristics using measurements of currently available FFRs has not been undertaken. Filter characteristics such as fiber diameter and filter depth were measured from samples taken from six currently-available N95 FFRs from three manufacturers. A filtration model was developed that included diffusion, inertial and electrostatic forces to estimate the filtration of an aerosol with a Boltzmann charge distribution. The diameter of the filter fibers was modeled as either a single "effective" diameter or as a lognormal distribution of diameters. Both modeling schemes produced an efficiency curve that simulated efficiency measurements made over a range of particle diameters (0.01 - 0.3 µm) with the use of a scanning mobility particle sizer in the region where efficiency is at a minimum. However, the method using a distribution of fiber diameters produced a better fit for particles > 0.1 µm. The coefficients associated with a simple form of the diffusion equation constituting a power law incorporating the Peclet number were adjusted to enhance model accuracy. Likewise, the fiber charge of the electret fibers was also adjusted to maximize model fit but remained within levels reported by others. A filter pressure drop model was also developed. Results demonstrated the need for a pressure drop model applicable to N95s relative to existing models developed with the use of fibers with larger diameters than those used in current N95 FFRs. A set of N95 FFR characteristics are provided that can be used to develop models of typical N95 FFR filter performance and pressure drop in future studies.

Indexed as

Air Pollutants, OccupationalRespiratory Protective DevicesAerosolsEquipment DesignFiltrationInhalation ExposureN95 RespiratorsNational Institute for Occupational Safety and Health, U.S.Particle SizeUnited StatesAerosolsAir Pollutants, OccupationalDiffusionfiber chargefiltrationpressure droprespirator

Identifiers

PMID37339509
PMCPMC10592347

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.