Evidence map›Paper›PMID 37336801›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

Unsupervised synthesis of realistic coronary artery X-ray angiogram.

Rémi Martin, Paul Segars, Ehsan Samei, Joaquim Miró, Luc Duong

Open access · greenAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Rémi MartinDepartment of Software and Information Technology Engineering, École de Technologie Supérieure, 1100 Notre-Dame, Montréal, QC, H3C 1K3, Canada. remi.martin.1@ens.etsmtl.ca.ORCID http://orcid.org/0000-0002-3557-1765
Paul SegarsCarl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, 2424 Erwin Road, Durham, NC, 27705, USA.
Ehsan SameiCarl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, 2424 Erwin Road, Durham, NC, 27705, USA.
Joaquim MiróDepartment of Pediatrics, CHU Sainte-Justine, 3175 Chem. de la Côte-Sainte-Catherine, Montréal, QC, H3T 1C5, Canada.
Luc DuongDepartment of Software and Information Technology Engineering, École de Technologie Supérieure, 1100 Notre-Dame, Montréal, QC, H3C 1K3, Canada.
Duke Medical Center · USÉcole de Technologie Supérieure · CACentre Hospitalier Universitaire Sainte-Justine · CA

Funding

TR&D Project 3: Virtual ReadersP41EB028744 · NIBIB · DUKE UNIVERSITY · PI Ehsan Samei · 2021 to 2026
$7.8M
Precision Cardiac CT: Development of a Computational Platform for Optimizing ImagingR01HL131753 · NHLBI · DUKE UNIVERSITY · PI SAMEI, EHSAN, SEGARS, WILLIAM P · 2017 to 2020
$2.7M
NHLBI NIH HHS R01 HL131753NIBIB NIH HHS P41 EB028744
6 · The paper itself

Abstract

purposeMedical image analysis suffers from a sparsity of annotated data necessary in learning-based models. Cardiorespiratory simulators have been developed to counter the lack of data. However, the resulting data often lack realism. Hence, the proposed method aims to synthesize realistic and fully customizable angiograms of coronary arteries for the training of learning-based biomedical tasks, for cardiologists performing interventions, and for cardiologist trainees.

methods3D models of coronary arteries are generated with a fully customizable realistic cardiorespiratory simulator. The transfer of X-ray angiography style to simulator-generated images is performed using a new vessel-specific adaptation of the CycleGAN model. The CycleGAN model is paired with a vesselness-based loss function that is designed as a vessel-specific structural integrity constraint.

resultsValidation is performed both on the style and on the preservation of the shape of the arteries of the images. The results show a PSNR of 14.125, an SSIM of 0.898, and an overlapping of 89.5% using the Dice coefficient.

conclusionWe proposed a novel fluoroscopy-based style transfer method for the enhancement of the realism of simulated coronary artery angiograms. The results show that the proposed model is capable of accurately transferring the style of X-ray angiograms to the simulations while keeping the integrity of the structures of interest (i.e., the topology of the coronary arteries).

Indexed as

Coronary VesselsImage Processing, Computer-AssistedCoronary AngiographyFluoroscopyHumansRadiographyX-RaysCardiorespiratory simulationsCoronary arteriesStyle transferX-ray angiography

Identifiers

PMID37336801
PMCPMC10786317
OpenAlexW4381185916

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.