Evidence map›Paper›PMID 37334315›Full record

ArticleAdvances in radiation oncology

Single-Pulse X-ray Acoustic Computed Tomographic Imaging for Precision Radiation Therapy.

Gilberto Gonzalez, Kiana Prather, Prabodh Kumar Pandey, Leshan Sun, Joseph Caron, Siqi Wang, Salahuddin Ahmad, Liangzhong Xiang, Yong Chen

Abstract read
In one paragraph

Article in Advances in radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. 4DPhysics in medicine and biology · 2024
    Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Gilberto GonzalezDepartment of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma.
Kiana PratherUniversity of Oklahoma College of Medicine, Oklahoma City, Oklahoma.
Prabodh Kumar PandeyDepartment of Radiological Sciences, University of California, Irvine, California.
Leshan SunDepartment of Biomedical Engineering, University of California, Irvine, California.
Joseph CaronDepartment of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma.
Siqi WangDepartment of Biomedical Engineering, University of California, Irvine, California.
Salahuddin AhmadDepartment of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma.
Liangzhong XiangDepartment of Radiological Sciences, University of California, Irvine, California.
Yong ChenDepartment of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma.

Funding

Univ.of Calif., Irvine Cancer Center Support GrantP30CA062203 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI Melanie Funes · 1994 to 2026
$57.9M
Academic-Industry Partnership for the Translation of a 4D in vivo Dosimetry Approach for Radiation TherapyR37CA240806 · NCI · UNIVERSITY OF OKLAHOMA · PI CHEN, YONG, IVANOV, VASSILI · 2019 to 2025
$2.9M
NCI NIH HHS P30 CA062203NCI NIH HHS R37 CA240806
6 · The paper itself

Abstract

Purpose: High-precision radiation therapy is crucial for cancer treatment. Currently, the delivered dose can only be verified via simulations with phantoms, and an in-tumor, online dose verification is still unavailable. An innovative detection method called x-ray-induced acoustic computed tomography (XACT) has recently shown the potential for imaging the delivered radiation dose within the tumor. Prior XACT imaging systems have required tens to hundreds of signal averages to achieve high-quality dose images within the patient, which reduces its real-time capability. Here, we demonstrate that XACT dose images can be reproduced from a single x-ray pulse (4 µs) with sub-mGy sensitivity from a clinical linear accelerator. Methods and Materials: By immersing an acoustic transducer in a homogeneous medium, it is possible to detect pressure waves generated by the pulsed radiation from a clinical linear accelerator. After rotating the collimator, signals of different angles are obtained to perform a tomographic reconstruction of the dose field. Using 2-stage amplification with further bandpass filtering increases the signal-to-noise ratio (SNR). Results: Acoustic peak SNR and voltage values were recorded for singular and dual-amplifying stages. The SNR for single-pulse mode was able to satisfy the Rose criterion, and the collected signals were able to reconstruct 2-dimensional images from the 2 homogeneous media. Conclusions: By overcoming the low SNR and requirement of signal averaging, single-pulse XACT imaging holds great potential for personalized dose monitoring from each individual pulse during radiation therapy.

Identifiers

PMID37334315
PMCPMC10276220

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.