ArticleJournal of orthopaedics2023
Influence of muscle traction on the primary stability of a reverse humeral prosthesis.
Article in Journal of orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Primary stability of an uncemented humeral stem in reverse shoulder arthroplasty for acute proximal humeral fractures: a prospective study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Currently, the influence of muscle traction on the postoperative stability of humeral prostheses is not adequately researched. This study analyzed the prosthesis' stability Methods: The reverse humeral prosthesis "AEQUALIS™ ADJUSTABLE REVERSED" (Stryker) was implanted using press-fit into ten bones with a length of 200 mm and 160 mm. Subsequently, the models were torqued in 30 cycles using a universal testing machine (2 Nm - 6 Nm) and loaded axially to simulate muscle traction. The axial weight increased from 7.7 kg (pure muscle traction) over 40 kg (45-degree abduction) to 69.3 kg (90-degree abduction). The prosthesis' relative micromotion was simultaneously measured at three different measurement heights using high-sensitivity displacement transducers and compared to the relative micromotion without axial load. Results: It was found that a larger torsional moment was associated with a larger relative micromotion in both bone defects studied. However, the influence became significant ( Conclusion: In conclusion, a larger torsional moment is associated with a higher relative micromotion and muscle traction, conclusively, has no effect on the primary stability of the reverse prosthesis for a 200 mm bone
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.