Evidence map›Paper›PMID 37332035›Full record

ArticleEuropean radiology experimental2023

Bridging the simulation-to-real gap for AI-based needle and target detection in robot-assisted ultrasound-guided interventions.

Visar Arapi, Alexander Hardt-Stremayr, Stephan Weiss, Jan Steinbrener

Erratum issuedAbstract read
In one paragraph

Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Visar ArapiControl of Networked Systems Research Group, Institute of Smart Systems Technologies, University of Klagenfurt, Klagenfurt, Austria. visar.arapi@aau.at.ORCID http://orcid.org/0000-0003-0266-185X
Alexander Hardt-StremayrControl of Networked Systems Research Group, Institute of Smart Systems Technologies, University of Klagenfurt, Klagenfurt, Austria.ORCID http://orcid.org/0000-0002-0464-5303
Stephan WeissControl of Networked Systems Research Group, Institute of Smart Systems Technologies, University of Klagenfurt, Klagenfurt, Austria.ORCID http://orcid.org/0000-0001-6906-5409
Jan SteinbrenerControl of Networked Systems Research Group, Institute of Smart Systems Technologies, University of Klagenfurt, Klagenfurt, Austria.ORCID http://orcid.org/0000-0002-2465-2527

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundArtificial intelligence (AI)-powered, robot-assisted, and ultrasound (US)-guided interventional radiology has the potential to increase the efficacy and cost-efficiency of interventional procedures while improving postsurgical outcomes and reducing the burden for medical personnel.

methodsTo overcome the lack of available clinical data needed to train state-of-the-art AI models, we propose a novel approach for generating synthetic ultrasound data from real, clinical preoperative three-dimensional (3D) data of different imaging modalities. With the synthetic data, we trained a deep learning-based detection algorithm for the localization of needle tip and target anatomy in US images. We validated our models on real, in vitro US data.

resultsThe resulting models generalize well to unseen synthetic data and experimental in vitro data making the proposed approach a promising method to create AI-based models for applications of needle and target detection in minimally invasive US-guided procedures. Moreover, we show that by one-time calibration of the US and robot coordinate frames, our tracking algorithm can be used to accurately fine-position the robot in reach of the target based on 2D US images alone.

conclusionsThe proposed data generation approach is sufficient to bridge the simulation-to-real gap and has the potential to overcome data paucity challenges in interventional radiology. The proposed AI-based detection algorithm shows very promising results in terms of accuracy and frame rate. RELEVANCE STATEMENT: This approach can facilitate the development of next-generation AI algorithms for patient anatomy detection and needle tracking in US and their application to robotics. KEY POINTS: • AI-based methods show promise for needle and target detection in US-guided interventions. • Publicly available, annotated datasets for training AI models are limited. • Synthetic, clinical-like US data can be generated from magnetic resonance or computed tomography data. • Models trained with synthetic US data generalize well to real in vitro US data. • Target detection with an AI model can be used for fine positioning of the robot.

Indexed as

Artificial IntelligenceRoboticsHumansNeedlesUltrasonographyUltrasonography, InterventionalCalibrationRadiology (interventional)RoboticsUltrasonography

Identifiers

PMID37332035
PMCPMC10277269

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.