Evidence map›Paper›PMID 37329389›Full record

ArticleJournal of clinical monitoring and computing2023

A technique to measure tidal volume during noninvasive respiratory support by continuous-flow helmet CPAP.

Andrea Coppadoro, Giacomo Bellani, Giuseppe Foti

Open access · hybridAbstract read
In one paragraph

Article in Journal of clinical monitoring and computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Andrea CoppadoroDepartment of Anesthesia and Intensive care, San Gerardo Hospital, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy.ORCID 0000-0003-1759-4071
Giacomo BellaniCentre for Medical Sciences - CISMed, University of Trento, Trento, Italy.ORCID 0000-0002-3089-205X
Giuseppe FotiDepartment of Anesthesia and Intensive care, San Gerardo Hospital, Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy. giuseppe.foti@unimib.it.ORCID 0000-0002-8698-2046
Azienda Ospedaliera San Gerardo · ITUniversity of Trento · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe coronavirus disease 2019 (COVID-19) pandemic has promoted the use of helmet continuous positive airway pressure (CPAP) for noninvasive respiratory support in hypoxic respiratory failure patients, despite the lack of tidal volume monitoring. We evaluated a novel technique designed to measure tidal volume during noninvasive continuous-flow helmet CPAP.

methodsA bench model of spontaneously breathing patients undergoing helmet CPAP therapy (three positive end-expiratory pressure [PEEP] levels) at different levels of respiratory distress was used to compare measured and reference tidal volumes. Tidal volume measurement by the novel technique was based on helmet outflow-trace analysis. Helmet inflow was increased from 60 to 75 and 90 L/min to match the patient's peak inspiratory flow; an additional subset of tests was conducted under the condition of purposely insufficient inflow (i.e., high respiratory distress and 60 L/min inflow).

resultsThe tidal volumes examined herein ranged from 250 to 910 mL. The Bland‒Altman analysis showed a bias of -3.2 ± 29.3 mL for measured tidal volumes compared to the reference, corresponding to an average relative error of -1 ± 4.4%. Tidal volume underestimation correlated with respiratory rate (rho = .411, p = .004) but not with peak inspiratory flow, distress, or PEEP. When the helmet inflow was maintained purposely low, tidal volume underestimation occurred (bias - 93.3 ± 83.9 mL), corresponding to an error of -14.8 ± 6.3%.

conclusionTidal volume measurement is feasible and accurate during bench continuous-flow helmet CPAP therapy by the analysis of the outflow signal, provided that helmet inflow is adequate to match the patient's inspiratory efforts. Insufficient inflow resulted in tidal volume underestimation. In vivo data are needed to confirm these findings.

Indexed as

Respiratory Distress SyndromeRespiratory InsufficiencyContinuous Positive Airway PressureHumansRespirationRespiratory RateTidal VolumeAcute hypoxemic respiratory failureContinuous flow Helmet CPAPNoninvasive respiratory supportSpontaneous breathingTidal volume respiratory monitoring

Identifiers

PMID37329389
PMCPMC10651536
OpenAlexW4381095255

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.