Evidence map›Paper›PMID 37329368›Full record

Observational studyKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023

Intraoperative control by Schanz-screws is inaccurate to achieve the exact amount of correction in de-rotational osteotomies.

Felix Ferner, Annett Klinder, Michael Woerner, Patrick Morris, Joerg Harrer, Joerg Dickschas, Christoph Lutter

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Felix FernerKlinik für Orthopädie, Unfallchirurgie, Handchirurgie, Regiomed Klinik Lichtenfels, Prof. Arneth Str. 2B, 96125, Lichtenfels, Germany. felix.ferner@gmx.de.
Annett KlinderOrthopädische Klinik und Poliklinik, Universität Rostock, Rostock, Germany.
Michael WoernerKlinik für Orthopädie und Unfallchirurgie, Sozialstiftung Bamberg, Bamberg, Germany.
Patrick MorrisKlinik für Orthopädie und Unfallchirurgie, Sozialstiftung Bamberg, Bamberg, Germany.
Joerg HarrerKlinik für Orthopädie, Unfallchirurgie, Handchirurgie, Regiomed Klinik Lichtenfels, Prof. Arneth Str. 2B, 96125, Lichtenfels, Germany.
Joerg DickschasKlinik für Orthopädie und Unfallchirurgie, Sozialstiftung Bamberg, Bamberg, Germany.
Christoph LutterOrthopädische Klinik und Poliklinik, Universität Rostock, Rostock, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe accuracy of intraoperative control of correction commonly is achieved by K-wires or Schanz-screws in combination with goniometer in de-rotational osteotomies. The purpose of this study is to investigate the accuracy of intraoperative torsional control in de-rotational femoral and tibial osteotomies. It is hypothesized, that intraoperative control by Schanz-screws and goniometer in de-rotational osteotomies around the knee is a safe and well predictable method to control the surgical torsional correction intraoperatively.

methods55 consecutive osteotomies around the knee joint were registered, 28 femoral and 27 tibial. The indication for osteotomy was femoral or tibial torsional deformity with the clinical occurrence of patellofemoral maltracking or PFI. Pre- and postoperative torsions were measured according to the method of Waidelich on computed tomography (CT) scan. The scheduled value of torsional correction was defined by the surgeon preoperatively. Intraoperative control of torsional correction was achieved by 5 mm-Schanz-screws and goniometer. The measured values of torsional CT scan were compared to the preoperative defined and intended values and deviation was calculated separately for femoral and tibial osteotomies.

resultsThe surgeon's intraoperative measured mean value of correction in all osteotomies was 15.2° (SD 4.6; range 10-27), whereas the postoperatively measured mean value on CT scan was 15.6 (6.8; 5.0-28.5). Intraoperatively the femoral mean value measured 17.9° (4.9; 10-27) and 12.4° (1.9; 10-15) for the tibia. Postoperatively the mean value for femoral correction was 19.8 (5.5; 9.0-28.5) and 11.3 (5.0; 5.0-26.0) for tibial correction. When considering a deviation of plus or minus 3° to be acceptable femorally 15 osteotomies (53.6%) and tibially 14 osteotomies (51.9%) fell within these limits. Nine femoral cases (32.1.%) were overcorrected, four cases undercorrected (14.3%). Four tibial cases of overcorrection (14.8%) and 9 tibial cases of undercorrection (33.3%) were observed. However, the observed difference between femur and tibia regarding the distribution of cases between the three groups did not reach significance. Moreover, there was no correlation between the extent of correction and the deviation from the intended result.

conclusionThe use of Schanz-screws and goniometer in de-rotational osteotomies as an intraoperative control of correction is an inaccurate method. Every surgeon performing derotational osteotomies must consider this and include postoperative torsional measurement in his postoperative algorithm until new tools or devices are available to guarantee a better intraoperative accuracy of torsional correction. STUDY

designObservational study. LEVEL OF EVIDENCE: III.

Indexed as

FemurTibiaBone ScrewsHumansKnee JointOsteotomyDe-rotational osteotomyIntraoperative measurementKnee osteotomyPatellofemoral instability

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.