Evidence map›Paper›PMID 37326696›Full record

ArticleInternational orthopaedics2023

Revision hip arthroplasty dislocation risk calculator: when to select dual mobility, large heads, constrained liners, or a standard head size? Testing one hundred thousand hip revisions with artificial intelligence.

Philippe Hernigou, Paul Tannyeres, Olivier Barbier, Philippe Chenaie

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Philippe HernigouUniversity Paris East, Paris, France. philippe.hernigou@wanadoo.fr.ORCID 0000-0002-8475-279X
Paul TannyeresHopital Sainte-Anne, Toulon, France.
Olivier BarbierHopital Sainte-Anne, Toulon, France.
Philippe ChenaieLaboratoire Bauerfeind, Tremblay, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePreventing dislocation with large head (≥ 36 mm), dual mobility, or constrained acetabular liner is another option than a standard (≤ 32 mm). Many other dislocations risk factors than size of the femoral head exist after hip arthroplasty revision. Predicting dislocation with a calculator according to the implant, to the indication of revision, and to patient's risks could allow a better surgery decision.

methodsOur search method covers the period from 2000 to 2022. A total of 470 relevant citations on hip major revision (cup or stem or both revisions) were identified with artificial intelligence comprising 235 publications of 54,742 standard heads comprising 142 publications of 35,270 large heads, comprising 41 publications of 3945 constrained acetabular components, and 52 publications of 10,424 dual mobility implants. We considered four implant types (standard, large head, dual mobility, or constrained acetabular liner) as the entry layer of the artificial neural network (ANN). Indication for revision THA was the second hidden layer. Demographics, spine surgery, and neurologic disease were the third layer. Implant revision, reconstruction process as next input (hidden layer). Surgery-related factors, and so on. The output was a postoperative dislocation or not.

resultsOf the 104,381 hips that underwent a major revision, a second revision for dislocation was performed for 9234 hips. In each implant group, dislocation remained the first cause of revision. The rate of second revision for dislocation as a percentage of first revision procedures was significantly higher in the standard head group (11.8%) than in the constrained acetabular liner group (4.5%), the dual mobility group (4.1%), and the large head group (6.1%). Instability of a previous THA, infection, or periprosthetic fracture as the indication for revision was increased risk factors as compared with aseptic loosening. One hundred variables were used to create the calculator with the best parameter combination of data and ranking the different factors, according to the four implant types (standard, large head, dual mobility, or constrained acetabular liner).

conclusionThe calculator can be used as a tool to identify patients at risk for dislocation after hip arthroplasty revision and individualize recommendations to select another option than a standard head size.

Indexed as

Arthroplasty, Replacement, HipHip DislocationHip ProsthesisJoint DislocationsArtificial IntelligenceHumansProsthesis DesignProsthesis FailureReoperationRetrospective StudiesRisk FactorsAseptic loosening revisionConstrained linerDislocation risk calculatorDual mobilityHip arthroplasty instability revisionHip revision dislocationInfection hip revisionLarge headsPeriprosthetic fractureSystematic review of review

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.