Evidence map›Paper›PMID 37325011›Full record

ArticlePractical laboratory medicine2023

Reducing blood sample hemolysis in the emergency department using S-Monovette® in aspiration mode.

Eunizar Omar, John Carson Allen, Ahmad Khairil Bin Mohamed Jamil, Mohamad Fahamy Koenitz Bin Iskandar, Kunzang Norbu, Connie Tsang, Jocelyn Yin, Sameera Ganti, Ong Siew Kim, Marcus Ong Eng Hock

Open access · goldAbstract read
In one paragraph

Article in Practical laboratory medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Eunizar OmarDepartment of Emergency Medicine, Sengkang General Hospital, Singapore.
John Carson AllenCentre for Quantitative Medicine, Singapore General Hospital, Singapore.
Ahmad Khairil Bin Mohamed JamilDepartment of Emergency Medicine, Sengkang General Hospital, Singapore.
Mohamad Fahamy Koenitz Bin IskandarDepartment of Emergency Medicine, Sengkang General Hospital, Singapore.
Kunzang NorbuDepartment of Emergency Medicine, Sengkang General Hospital, Singapore.
Connie TsangDepartment of Emergency Medicine, Sengkang General Hospital, Singapore.
Jocelyn YinDepartment of Emergency Medicine, Sengkang General Hospital, Singapore.
Sameera GantiDepartment of Emergency Medicine, Sengkang General Hospital, Singapore.
Ong Siew KimDepartment of Pathology, Sengkang General Hospital, Singapore.
Marcus Ong Eng HockDuke-NUS Medical School, Singapore.
Sengkang General Hospital · SGSingapore General Hospital · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Blood sample hemolysis continues to be a significant problem in clinical practice. Methods: This was a prospective randomised controlled study conducted in an Emergency department (ED). A convenience sample of 191 adult patients, aged 18-90 years old, presenting at the ED and requiring blood samples for serum electrolyte was included in the study. Paired blood samples were obtained through an intravenous cannula from each patient with randomised order of blood draw using SMA or BDV. Patient data was obtained and hemolysis index (HI), serum lactate dehydrogenase (LDH), and serum potassium (K) levels measured. Results: The adjusted mean HI (35.2 vs 21.5 mg/dL, p < 0.001), serum K (4.38 vs 4.16 mmol/L, p < 0.001) and LDH levels (259.6 vs 228.4 U/L, p < 0.001) were significantly higher in blood samples taken using BDV compared to SMA. The frequency of severely hemolyzed (>150 mg/dL) samples was also higher in blood collected using BDV (16.2%) compared to SMA (0%). Conclusions: The burden of hemolysis in blood samples taken from IV cannulae can be effectively reduced with the use of manual aspiration using the S-Monovette® blood collection system as compared to BD-Vacutainer.

Indexed as

Blood samplingHemolysisIntravenous cannulaVacuum collection system

Identifiers

PMID37325011
PMCPMC10265510
OpenAlexW4378194647

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.