Evidence map›Paper›PMID 37324756›Full record

ArticleJournal of arrhythmia2023

Procedural performance between two cryoballoon systems for ablation of atrial fibrillation depends on pulmonary vein anatomy.

Vincent Menger, Michael Frick, Ahmad Sharif-Yakan, Mahdi Emrani, Matthias Daniel Zink, Andreas Napp, Nikolaus Marx, Michael Gramlich

Open access · goldAbstract read
In one paragraph

Article in Journal of arrhythmia, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Novel or established cryoballoon ablation system for pulmonary vein isolation: the prospective ICE-AGE-1 study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Vincent MengerDepartment of Cardiology University Hospital RWTH Aachen Aachen Germany.ORCID https://orcid.org/0000-0001-5859-9552
Michael FrickDepartment of Cardiology University Hospital RWTH Aachen Aachen Germany.
Ahmad Sharif-YakanDepartment of Cardiology University Hospital RWTH Aachen Aachen Germany.
Mahdi EmraniDepartment of Cardiology University Hospital RWTH Aachen Aachen Germany.
Matthias Daniel ZinkDepartment of Cardiology University Hospital RWTH Aachen Aachen Germany.
Andreas NappDepartment of Cardiology University Hospital RWTH Aachen Aachen Germany.
Nikolaus MarxDepartment of Cardiology University Hospital RWTH Aachen Aachen Germany.
Michael GramlichDepartment of Cardiology University Hospital RWTH Aachen Aachen Germany.ORCID https://orcid.org/0000-0001-5233-6778
RWTH Aachen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Cryoballoon ablation is a first-line therapy for atrial fibrillation. We compared the efficacy and safety of two ablation systems and addressed the influence of pulmonary vein (PV) anatomy on performance and outcome. Methods: We consecutively enrolled 122 patients who were planned for first-time cryoballoon ablation. Patients were assigned 1:1 for ablation with the POLARx or the Arctic Front Advance Pro (AFAP) system and followed-up for 12 months. Procedural parameters were recorded during the ablation. Before the procedure, a magnetic resonance angiography (MRA) of the PVs was generated and diameter, area, and shape of each PV ostium were assessed. We applied an evaluated PV anatomical scoring system on our MRA measurement data ranging from 0 (best anatomical combination) to 5. Results: Procedures performed with POLARx were associated with shorter time to balloon temperature -30°C ( Conclusion: We found significant differences in cooling kinetics, especially when anatomical conditions are difficult. However, both systems have a comparable outcome and safety profile.

Indexed as

atrial fibrillationcryoablationpulmonary vein anatomy

Identifiers

PMID37324756
PMCPMC10264750
OpenAlexW4327723557

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.