Evidence map›Paper›PMID 37323755›Full record

ArticleIEEE transactions on industrial electronics (1982)2023

SAPM: Self-Adaptive Parallel Manipulator with Pose and Force Adjustment for Robotic Ultrasonography.

Xianqiang Bao, Shuangyi Wang, Lingling Zheng, Richard James Housden, Joseph Hajnal, Kawal Rhode

Abstract read
In one paragraph

Article in IEEE transactions on industrial electronics (1982), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Development of a Highly Adaptive Miniature Piezoelectric Robot Inspired by Earthworms.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  4. Review
  5. Developments and Challenges of Miniature Piezoelectric Robots: A Review.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xianqiang BaoSchool of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EH, United Kingdom.
Shuangyi WangState Key Laboratory of Management and Control for Complex Systems, Institute of Automation, Chinese Academy of Sciences, Beijing, 100190, China.
Lingling ZhengFaculty of Engineering and Design, Kagawa University, Takamatsu 761-0396, Japan.
Richard James HousdenSchool of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EH, United Kingdom.
Joseph HajnalSchool of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EH, United Kingdom.
Kawal RhodeSchool of Biomedical Engineering & Imaging Sciences, King's College London, SE1 7EH, United Kingdom.

Funding

Wellcome Trust
6 · The paper itself

Abstract

Robotic ultrasonography potentially acts as an essential aid to medical diagnosis. To overcome the limitations in robotic ultrasonography, in this paper, we proposed a novel self-adaptive parallel manipulator (SAPM) that can automatically adjust the ultrasound (US) probe pose to adapt to various contours of scanned areas, provide approximate constant operating forces/torques, achieve mechanical measurement, and cushion undesired produced forces. A novel parallel adjustment mechanism is proposed to attain automatic pose adjustment with 3 degrees of freedom (DOFs). This mechanism enables the US probe to adapt to different scanned areas and to perform the scanning with approximate constant forces and torques. Besides, we present a mechanical measurement and safety protection method that can be integrated into the SAPM and used as operation status monitoring and early warning during scanning procedures by capturing operating forces and torques. Experiments were carried out to calibrate the measurement and buffer units and evaluate the performance of the SAPM. Experimental results show the ability of the SAPM to provide 3-DoFs motion and operating force/torque measurement and automatically adjust the US probe pose to capture US images of equally good quality compared to a manual sonographer scan. Moreover, it has characteristics similar to soft robots that could significantly improve operation safety, and could be extended to some other engineering or medical applications.

Indexed as

automatic pose adjustmentconstant forces/torquesmechanical measurementoperation safetyRobotic ultrasonography

Identifiers

PMID37323755
PMCPMC7614654

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.