Evidence map›Paper›PMID 37323532›Full record

ArticleEuropean heart journal. Case reports2023

Transseptal snaring technique as a bailout from valvuloplasty balloon entrapment within a self-expanding valve: a case report.

Yoichi Sugiyama, Noriaki Moriyama, Juho Viikilä, Pekka Raatikainen

Open access · goldAbstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 84% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Yoichi SugiyamaDepartment of Cardiology, Heart and Lung Center, Helsinki University and Helsinki University Central Hospital, Haartmaninkatu 4, 00290 Helsinki, Finland.ORCID https://orcid.org/0000-0001-8363-9632
Noriaki MoriyamaDepartment of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, 1370-1 Okamoto, Kamakura, Kanagawa 247-8533, Japan.ORCID https://orcid.org/0000-0002-8570-5901
Juho ViikiläDepartment of Cardiology, Heart and Lung Center, Helsinki University and Helsinki University Central Hospital, Haartmaninkatu 4, 00290 Helsinki, Finland.
Pekka RaatikainenDepartment of Cardiology, Heart and Lung Center, Helsinki University and Helsinki University Central Hospital, Haartmaninkatu 4, 00290 Helsinki, Finland.
Helsinki University Hospital · FIShonan Kamakura General Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transcatheter aortic valve replacement (TAVR) has become the dominant treatment strategy for severe aortic stenosis in patients with high and intermediate surgical risk. Although complications are significant cause of increasing mortality after TAVR and bailout techniques have been well established, we still encounter a rare complication without widely accepted bailout option. We present a rare complication of valvuloplasty balloon entrapment to a self-expanding valve strut with successful bailout. Case summary: A 71-year-old man complaining of dyspnoea underwent valve-in-valve TAVR for failed surgical aortic valve. However, he developed acute decompensated heart failure due to high residual aortic gradient (peak aortic velocity of 4.0 m/s and mean aortic gradient of 37 mmHg) on the 3rd day after TAVR. Computed tomography demonstrated underexpansion of transcatheter heart valve (THV) within the surgical valve. Therefore, urgent balloon valvuloplasty was performed. The balloon entrapment in the THV stent frame happened during the procedure. Percutaneous removal through transseptal approach using snaring technique was successfully performed. Discussion: Balloon entrapment within a THV is a rare complication and potentially requires urgent surgical removal. To our knowledge, this is the first report utilizing the snaring technique through transseptal approach for balloon entrapment within a THV. Through the current report, we highlight the utility and effectiveness of the transseptal snaring technique with using a steerable transseptal sheath. Moreover, this case shows the importance of the multiprofessional approach to resolve unexpected complications.

Indexed as

Case reportComplicationTranscatheter aortic valve replacementTransseptal snaring techniqueValvuloplasty balloon entrapment

Identifiers

PMID37323532
PMCPMC10267621
OpenAlexW4379054113

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.