Evidence map›Paper›PMID 37323501›Full record

ArticleInternational journal of bioprinting2023

Design and biomechanical analysis of patientspecific porous tantalum prostheses for knee joint revision surgery.

Shilong Mao, Yang Liu, Fuyou Wang, Peng He, Xianzhe Wu, Xingshuang Ma, Yanfeng Luo

Open access · diamondAbstract read
In one paragraph

Article in International journal of bioprinting, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Shilong MaoCollege of Bioengineering, Chongqing University; Key Laboratory of Biorheological Science and Technology (Chongqing University), Ministry of Education, Chongqing, 400030, China.
Yang LiuCollege of Bioengineering, Chongqing University; Key Laboratory of Biorheological Science and Technology (Chongqing University), Ministry of Education, Chongqing, 400030, China.
Fuyou WangSouthwest Hospital of Army Medical University, Chongqing, 400038, China.
Peng HeChongqing Institute of Optics and Mechanics, Chongqing, 401122, China.
Xianzhe WuChongqing Institute of Optics and Mechanics, Chongqing, 401122, China.
Xingshuang MaCollege of Bioengineering, Chongqing University; Key Laboratory of Biorheological Science and Technology (Chongqing University), Ministry of Education, Chongqing, 400030, China.
Yanfeng LuoCollege of Bioengineering, Chongqing University; Key Laboratory of Biorheological Science and Technology (Chongqing University), Ministry of Education, Chongqing, 400030, China.
Southwest Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Artificial joint revision surgery, as an increasingly common surgery in orthopedics, often requires patient-specific prostheses to repair the bone defect. Porous tantalum is a good candidate due to its excellent abrasion and corrosion resistance and good osteointegration. Combination of 3D printing technology and numerical simulation is a promising strategy to design and prepare patient-specific porous prostheses. However, clinical design cases have rarely been reported, especially from the viewpoint of biomechanical matching with the patient's weight and motion and specific bone tissue. This work reports a clinical case on the design and mechanical analysis of 3D-printed porous tantalum prostheses for the knee revision of an 84-year-old male patient. Particularly, standard cylinders of 3D-printed porous tantalum with different pore size and wire diameters were first fabricated and their compressive mechanical properties were measured for following numerical simulation. Subsequently, patientspecific finite element models for the knee prosthesis and the tibia were constructed from the patient's computed tomography data. The maximum von Mises stress and displacement of the prostheses and tibia and the maximum compressive strain of the tibia were numerically simulated under two loading conditions by using finite element analysis software ABAQUS. Finally, by comparing the simulated data to the biomechanical requirements for the prosthesis and the tibia, a patient-specific porous tantalum knee joint prosthesis with a pore diameter of 600 μm and a wire diameter of 900 μm was determined. The Young's modulus (5719.32 ± 100.61 MPa) and yield strength (172.71 ± 1.67 MPa) of the prosthesis can produce both sufficient mechanical support and biomechanical stimulation to the tibia. This work provides a useful guidance for designing and evaluating a patient-specific porous tantalum prosthesis.

Indexed as

Artificial joint revision surgeryBiomechanicsFinite element analysisPorous tantalum

Identifiers

PMID37323501
PMCPMC10261154
OpenAlexW4380870562

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.