Evidence map›Paper›PMID 37315077›Full record

Trial reportPloS one2023

Speech-in-noise performance in objectively determined cochlear implant maps, including the effect of cognitive state.

Jessica M Yiannos, Christofer W Bester, Christopher Zhao, Barbara Gell, Dona M P Jayakody

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Montreal cognitive assessment scores predict long-term speech recognition in noise and can be used to guide rehabilitation of cochlear implant users.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jessica M YiannosEar Science Institute Australia, Subiaco, Western Australia, Australia.
Christofer W BesterEar Science Institute Australia, Subiaco, Western Australia, Australia.ORCID 0000-0003-2246-1177
Christopher ZhaoSchool of Human Sciences, University of Western Australia, Crawley, Western Australia, Australia.
Barbara GellMED-EL Australasia, Alexandria, New South Wales, Australia.
Dona M P JayakodyEar Science Institute Australia, Subiaco, Western Australia, Australia.ORCID 0000-0001-5814-4355

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveCochlear Implant (CI) programming based on subjective psychophysical fine-tuning of loudness scaling involves active participation and cognitive skills and thus may not be appropriate for difficult-to-condition populations. The electrically evoked stapedial reflex threshold (eSRT) is an objective measure that is suggested to provide clinical benefit to CI programming. This study aimed to compare speech reception outcomes between subjective and eSRT objectively determined CI maps for adult MED-EL recipients. The effect of cognitive skills on these skills was further assessed.

methodsTwenty-seven post lingually hearing-impaired MED-EL CI recipients were recruited, 6 with mild cognitive impairment (MCI- 4 male, 79 years ± 5), 21 with normal cognitive function (5 male, 63 years ± 12). Two MAPs were generated: a subjective MAP and an objective MAP in which eSRTs determined maximum comfortable levels (M-Levels). Participants were randomly divided into two groups. Group A trialled the objective MAP for two weeks before returning for outcome assessment. During the following two weeks, Group A trialled the subjective MAP before returning for outcome assessment. Group B trialled MAPs in reverse. Outcome measures included the Hearing Implant Sound Quality Index (HISQUI), Consonant-Nucleus-Consonant (CNC) word test, and Bamford-Kowal-Bench Speech-in-Noise (BKB-SIN) test.

resultseSRT based MAPS were obtained in 23 of the participants. A strong relationship was demonstrated between global charge between eSRT-based and psychophysical-based M-Levels (r = 0.89, p < .001). The Montreal Cognitive Assessment for the Hearing Impaired (MoCA-HI) testing identified 6 CI recipients with MCI (MoCA-HI total score ≤23). The MCI group was older (63, 79 years), but were not otherwise different in sex, duration of hearing loss or duration of CI use. For all patients, no significant differences were found for sound quality or speech in quiet scores between eSRT-based and psychophysical-based MAPs. However, psychophysically determined MAPs showed significantly better speech-in-noise reception (6.74 vs 8.20-dB SNR, p = .34). MoCA-HI scores showed a significant, moderate negative correlation with BKB SIN for both MAP approaches (Kendall's Tau B, p = .015 and p = .008), with no effect on the difference between MAP approaches.

conclusionResults indicate eSRT-based methods provide poorer outcomes than psychophysical-based method. While speech-in-noise reception is correlated with MoCA-HI score, this affected both behaviourally and objectively determined MAPs. The results suggest fair confidence in the eSRT-based method as a guide for setting M-Level for difficult-to-condition CI populations in simple listening conditions.

Indexed as

Cochlear ImplantationCochlear ImplantsAdultCognitionHumansMaleSoundSpeech

Identifiers

PMID37315077
PMCPMC10266623

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.