Evidence map›Paper›PMID 37314663›Full record

ArticleAnnals of biomedical engineering2023

Micromechanical Loading Studies in Ex Vivo Cultured Embryonic Rat Bones Enabled by a Newly Developed Portable Loading Device.

Zhengpei Zhang, Farasat Zaman, Tobia Sebastiano Nava, Tim R J Aeppli, Elena M Gutierrez-Farewik, Artem Kulachenko, Lars Sävendahl

Open access · hybridAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. The Ex Vivo Organ Culture of Bone and Cartilage.Methods in molecular biology (Clifton, N.J.) · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Zhengpei ZhangDivision of Pediatric Endocrinology, Department of Women's and Children's Health, Karolinska Institutet, Solna, Sweden. Zhengpei.zhang@ki.se.
Farasat ZamanDivision of Pediatric Endocrinology, Department of Women's and Children's Health, Karolinska Institutet, Solna, Sweden. Farasat.zaman@ki.se.
Tobia Sebastiano NavaKTH MoveAbility Lab, Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
Tim R J AeppliDivision of Pediatric Endocrinology, Department of Women's and Children's Health, Karolinska Institutet, Solna, Sweden.
Elena M Gutierrez-FarewikKTH MoveAbility Lab, Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
Artem KulachenkoSolid Mechanics Unit, Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
Lars SävendahlDivision of Pediatric Endocrinology, Department of Women's and Children's Health, Karolinska Institutet, Solna, Sweden.
Karolinska Institutet · SEKTH Royal Institute of Technology · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mechanical loading has been described as having the potential to affect bone growth. In order to experimentally study the potential clinical applications of mechanical loading as a novel treatment to locally modulate bone growth, there is a need to develop a portable mechanical loading device enabling studies in small bones. Existing devices are bulky and challenging to transfer within and between laboratories and animal facilities, and they do not offer user-friendly mechanical testing across both ex vivo cultured small bones and in vivo animal models. To address this, we developed a portable loading device comprised of a linear actuator fixed within a stainless-steel frame equipped with suitable structures and interfaces. The actuator, along with the supplied control system, can achieve high-precision force control within the desired force and frequency range, allowing various load application scenarios. To validate the functionality of this new device, proof-of-concept studies were performed in ex vivo cultured rat bones of varying sizes. First, very small fetal metatarsal bones were microdissected and exposed to 0.4 N loading applied at 0.77 Hz for 30 s. When bone lengths were measured after 5 days in culture, loaded bones had grown less than unloaded controls (p < 0.05). Next, fetal rat femur bones were periodically exposed to 0.4 N loading at 0.77 Hz while being cultured ex vivo for 12 days. Interestingly, this loading regimen had the opposite effect on bone growth, i.e., loaded femur bones grew significantly more than unloaded controls (p < 0.001). These findings suggest that complex relationships between longitudinal bone growth and mechanical loading can be determined using this device. We conclude that our new portable mechanical loading device allows experimental studies in small bones of varying sizes, which may facilitate further preclinical studies exploring the potential clinical applications of mechanical loading.

Indexed as

Mechanical PhenomenaMetatarsal BonesAnimalsBone DevelopmentFetusRatsStress, MechanicalWeight-BearingBone growthBone organ cultureDynamic loadFemurMetatarsal

Identifiers

PMID37314663
PMCPMC10518283
OpenAlexW4380577145

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.