Evidence map›Paper›PMID 37314488›Full record

ArticleJournal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie2024

Surface wear and adhesive failure of resin attachments used in clear aligner orthodontic treatment.

Alexandre Fausto da Veiga Jardim, Jairo Curado de Freitas, Carlos Estrela

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07215598 (Accuracy of Invisalign Attachments), which is not on this map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07215598 naenrolling by invitationnot on this mapstarted 2025, after this paper: background citation

Accuracy of Invisalign Attachments: A Split-Mouth Comparative Study of Optimized and Conventional Designs

TypeinterventionalSponsorUniversity of Maryland, BaltimoreRan2025 to 2028Enrolled30ConditionsWear, Restoration, Volume Assessment, Clear Aligner ApplianceArmsComposite Aligner Attachment
3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Alexandre Fausto da Veiga JardimDepartment of Stomatologic Sciences, Federal University of Goiás, Av. Universitária, s/n-Setor Leste Universitário, 74605-020, Goiânia, Brazil. alexandre.fvj@gmail.com.ORCID http://orcid.org/0000-0001-5673-1345
Jairo Curado de FreitasDepartment of Stomatologic Sciences, Federal University of Goiás, Av. Universitária, s/n-Setor Leste Universitário, 74605-020, Goiânia, Brazil.
Carlos EstrelaDepartment of Stomatologic Sciences, Federal University of Goiás, Av. Universitária, s/n-Setor Leste Universitário, 74605-020, Goiânia, Brazil.ORCID http://orcid.org/0000-0002-1488-0366

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study evaluated adhesive and cohesive failures and the surface wear of attachments employed in clear aligner treatment (CAT) using three-dimensional (3D) superimposition.

methodsIn all, 3D models of 150 teeth were obtained from intraoral scans from patients undergoing CAT with at least 4 months between each scan. Of the initial sample, 25 teeth were discarded, and 125 teeth were included in the study. Superimpositions of each individual tooth at the first and second time points were made using computer-aided design (CAD) software (Meshmixer; Autodesk, Mill Valley, CA, USA). Analyses were performed to compare surface wear and failures related to type of attachment (optimized/conventional), dental group (molars/premolars/anterior teeth), and arch (mandibular/maxillary). Mann-Whitney and Kruskal-Wallis statistical tests were applied with significance set at 5%.

resultsMore surface wear was observed in conventional attachments, mandibular and anterior teeth with statistical significance for surface wear on the distal surface of conventional attachments (p < 0.05). Cohesive failure was observed in 10% of attachments, occurring most frequently on optimized attachments and molar teeth. Adhesive failure was observed in 10% of the samples, more frequently on conventional attachments and posterior teeth.

conclusionAttachment type (conventional vs. optimized) was significantly correlated with surface wear on the distal surface of the attachment. Arch (mandibular or maxillary) and group of teeth (anterior or posterior) showed no correlation with surface wear. Failure, both adhesive and cohesive, correlated with attachment type and group of teeth, but not with the arch in which they were located.

Indexed as

Orthodontic Appliances, RemovableComputer-Aided DesignFemaleHumansImaging, Three-DimensionalMaleSurface PropertiesTooth Movement TechniquesComposite resinComputer-aided designDental auxiliariesOrthodontic forcesOrthodontic treatment

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.