Evidence map›Paper›PMID 37313666›Full record

ArticleAcute and critical care2023

Evaluating diaphragmatic dysfunction and predicting non-invasive ventilation failure in acute exacerbation of chronic obstructive pulmonary disease in India.

Nupur B Patel, Gaurav Jain, Udit Chauhan, Ajeet Singh Bhadoria, Saurabh Chandrakar, Haritha Indulekha

Abstract read
In one paragraph

Article in Acute and critical care, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nupur B PatelDepartment of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
Gaurav JainDepartment of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
Udit ChauhanDepartment of Radiodiagnosis, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
Ajeet Singh BhadoriaDepartment of Community and Family Medicine, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
Saurabh ChandrakarDepartment of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
Haritha IndulekhaDepartment of Anesthesiology and Critical Care, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBaseline diaphragmatic dysfunction (DD) at the initiation of non-invasive ventilation (NIV) correlates positively with subsequent intubation. We investigated the utility of DD detected 2 hours after NIV initiation in estimating NIV failure in acute exacerbation of chronic obstructive pulmonary disease (AECOPD) patients.

methodsIn a prospective-cohort design, we enrolled 60 consecutive patients with AECOPD initiated on NIV at intensive care unit admission, and NIV failure events were noted. The DD was assessed at baseline (T1 timepoint) and 2 hours after initiating NIV (T2 timepoint). We defined DD as ultrasound-assessed change in diaphragmatic thickness (ΔTDI) <20% (predefined criteria [PC]) or its cut-off that predicts NIV failure (calculated criteria [CC]) at both timepoints. A predictive-regression analysis was reported.

resultsIn total, 32 patients developed NIV failure, nine within 2 hours of NIV and remaining in next 6 days. The ∆TDI cut-off that predicted NIV failure (DD-CC) at T1 was ≤19.04% (area under the curve [AUC], 0.73; sensitivity, 50%; specificity, 85.71%; accuracy; 66.67%), while that at T2 was ≤35.3% (AUC, 0.75; sensitivity, 95.65%; specificity, 57.14%; accuracy, 74.51%; hazard ratio, 19.55). The NIV failure rate was 35.1% in those with normal diaphragmatic function by PC (T2) versus 5.9% by CC (T2). The odds ratio for NIV failure with DD criteria ≤35.3 and <20 at T2 was 29.33 and 4.61, while that for ≤19.04 and <20 at T1 was 6, respectively.

conclusionsThe DD criterion of ≤35.3 (T2) had a better diagnostic profile compared to baseline and PC in prediction of NIV failure.

Indexed as

chronic obstructive pulmonary diseasediaphragmatic dysfunctiondiaphragmatic thicknessintubationnon-invasive ventilation

Identifiers

PMID37313666
PMCPMC10265417

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.