Evidence map›Paper›PMID 37312896›Full record

ArticleJournal of biomedical physics & engineering2023

Dosimetry Evaluation of Treatment Planning Systems in Patient-Specific 3D Printed Anthropomorphic Phantom for Breast Cancer after Mastectomy using a Single-Beam 3D-CRT Technique for Megavoltage Electron Radiation Therapy.

Endarko Endarko, Siti Aisyah, Aditya Prayugo Hariyanto, Mohammad Haekal, Nandia Kavilani, Ahmad Syafi'i

Abstract read
In one paragraph

Article in Journal of biomedical physics & engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Endarko EndarkoDepartment of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS - Sukolilo Surabaya 60111, East Java, Indonesia.
Siti AisyahMedical Physicist of Radiotherapy Installation, Naval Hospital Dr. Ramelan, Surabaya 60244, East Java, Indonesia.
Aditya Prayugo HariyantoDepartment of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS - Sukolilo Surabaya 60111, East Java, Indonesia.
Mohammad HaekalDepartment of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS - Sukolilo Surabaya 60111, East Java, Indonesia.
Nandia KavilaniMedical Physicist of Radiotherapy Installation, Naval Hospital Dr. Ramelan, Surabaya 60244, East Java, Indonesia.
Ahmad Syafi'iMedical Physicist of Radiotherapy Installation, Naval Hospital Dr. Ramelan, Surabaya 60244, East Java, Indonesia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The patient-specific 3D printed anthropomorphic phantom is used for breast cancer after mastectomy developed by the laboratory of medical physics and biophysics, Department of Physics, Institut Teknologi Sepuluh Nopember, Indonesia. This phantom is applied to simulate and measure the radiation interactions occurring in the human body either using the treatment planning system (TPS) or direct measurement with external beam therapy (EBT) 3 film. Objective: This study aimed to provide dose measurements in the patient-specific 3D printed anthropomorphic phantom using a TPS and direct measurements using single-beam three-dimensional conformal radiation therapy (3DCRT) technique with electron energy of 6 MeV. Material and Methods: In this experimental study, the patient-specific 3D printed anthropomorphic phantom was used for post-mastectomy radiation therapy. TPS on the phantom was conducted using a 3D-CRT technique with RayPlan 9A software. The single-beam radiation was delivered to the phantom with an angle perpendicular to the breast plane at 337.3° at 6 MeV with a total prescribed dose of 5000 cGy/25 fractions with 200 cGy per fraction. Results: The doses at planning target volume (PTV) and right lung confirmed a non-significant difference both for TPS and direct measurement with Conclusion: The patient-specific 3D printed anthropomorphic phantom for breast cancer after mastectomy on the right side has good potential as an alternative to the evaluation of dosimetry for radiation therapy.

Indexed as

DosimetryEBT3ElectronsEnergyMastectomyPhantomRadiationThree-Dimensional Therapy

Identifiers

PMID37312896
PMCPMC10258204

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.